background image

Figure 3: Connection diagram for insert 

Connect the shutter motor and power supply unit (8) to the insert (1) according to the 
connection diagram (Figure 3).  

For a shutter cover with sensor evaluation, install the sensor cable in accordance with 
(Figure 8) or (Figure 9) (Installing the sensor cable). 

If necessary connect extension (Figure 4). 

Install insert in appliance box, terminals must be at the bottom. 

Attach the frame and the cover.  

Check function. If the blind/shutter moves in the wrong direction, exchange the 
connections. 

Connecting an extension 

DANGER! 
Danger of electrical shock when 230 V is connected to the extension inputs! 
Electrical shocks can be fatal. 
Do not connect the extension inputs with 230 V extensions or other 230 V  
components. 

The extension inputs "1" and "2" may only be connected to DC 24 V SELV. 

32545312 

10499098  I00 

17.05.2011 

3/8 

Blind control system 

Blind controller insert DC 24 V 

Содержание 0388 00

Страница 1: ...tter motors or awnings Do not use it to switch other loads Use only Venetian blind drives with mechanical or electronic limit switches Check the limit switches for correct adjustment Observe the speci...

Страница 2: ...tom of cover for longer than one second The Venetian blind moves in the desired direction to the end position or stops when the button is pressed again Adjusting the slats o Press top or bottom of cov...

Страница 3: ...n appliance box terminals must be at the bottom o Attach the frame and the cover o Check function If the blind shutter moves in the wrong direction exchange the connections Connecting an extension DAN...

Страница 4: ...or is determined by the polarity of the two extension inputs Connection illustration Figure 4 shows the direction of motion of the blind shutter for the depicted connection assignments Figure 5 Insert...

Страница 5: ...h extension inputs Figure 7 Connection diagram for two inserts supplied via two power supply units o Connect extension according to connection diagram Figure 5 Figure 6 or Figure 7 Installing the sens...

Страница 6: ...the sensor cable use only shielded cables Recommendation J Y ST Y 2x2x0 6 mm o Insert the cable through the hole 11 in the insert and route it through the cable duct 12 to the terminal block 13 Figur...

Страница 7: ...e earth is identified For the adapter and the extension cable the sun is identified The earth is the middle cable i Interchanging the connections will result in malfunctions i If the sun and glass bre...

Страница 8: ...mm 6 2 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to you...

Отзывы: