Figure 3: Connection diagram for insert
o
Connect the shutter motor and power supply unit (8) to the insert (1) according to the
connection diagram (Figure 3).
o
For a shutter cover with sensor evaluation, install the sensor cable in accordance with
(Figure 8) or (Figure 9) (Installing the sensor cable).
o
If necessary connect extension (Figure 4).
o
Install insert in appliance box, terminals must be at the bottom.
o
Attach the frame and the cover.
o
Check function. If the blind/shutter moves in the wrong direction, exchange the
connections.
Connecting an extension
DANGER!
Danger of electrical shock when 230 V is connected to the extension inputs!
Electrical shocks can be fatal.
Do not connect the extension inputs with 230 V extensions or other 230 V
components.
The extension inputs "1" and "2" may only be connected to DC 24 V SELV.
32545312
10499098 I00
17.05.2011
3/8
Blind control system
Blind controller insert DC 24 V