Product characteristics 

Integration into groups or master control via extension units with additional 24 V inserts 

Operation as a main device or extension unit 

Supports sensor functions of the cover 

Several motors can be connected in parallel 

The direction of rotation of the shutter motor is determined by switching the polarity of the 
motor outputs "pole-changing principle" (Figure 2) 

Figure 2: Control of the shutter motor 

(6)  Relay contacts for moving up 
(7)  Relay contacts for moving down 

4 Operation 

Moving the blind/shutter 

Press top or bottom of cover for longer than one second. 
The Venetian blind moves in the desired direction to the end position or stops when the 
button is pressed again. 

Adjusting the slats 

Press top or bottom of cover for shorter than one second. 
The slat position changes in the desired direction for as long as the button is pressed. 

Moving the blind/shutter via a mechanical extension 

Press the button for moving up or down until the blind/shutter has reached the desired 
position. 

5 Information for electrically skilled persons 

5.1 Fitting and electrical connection 

Connecting and mounting the insert 

Operate the insert only with a DC 24 V SELV power supply unit. 

32545312 

10499098  I00 

17.05.2011 

2/8 

Blind control system 

Blind controller insert DC 24 V 

Содержание 0388 00

Страница 1: ...tter motors or awnings Do not use it to switch other loads Use only Venetian blind drives with mechanical or electronic limit switches Check the limit switches for correct adjustment Observe the speci...

Страница 2: ...tom of cover for longer than one second The Venetian blind moves in the desired direction to the end position or stops when the button is pressed again Adjusting the slats o Press top or bottom of cov...

Страница 3: ...n appliance box terminals must be at the bottom o Attach the frame and the cover o Check function If the blind shutter moves in the wrong direction exchange the connections Connecting an extension DAN...

Страница 4: ...or is determined by the polarity of the two extension inputs Connection illustration Figure 4 shows the direction of motion of the blind shutter for the depicted connection assignments Figure 5 Insert...

Страница 5: ...h extension inputs Figure 7 Connection diagram for two inserts supplied via two power supply units o Connect extension according to connection diagram Figure 5 Figure 6 or Figure 7 Installing the sens...

Страница 6: ...the sensor cable use only shielded cables Recommendation J Y ST Y 2x2x0 6 mm o Insert the cable through the hole 11 in the insert and route it through the cable duct 12 to the terminal block 13 Figur...

Страница 7: ...e earth is identified For the adapter and the extension cable the sun is identified The earth is the middle cable i Interchanging the connections will result in malfunctions i If the sun and glass bre...

Страница 8: ...mm 6 2 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to you...

Отзывы: