Oversink and Undersink Water Heater
- 13-
4.6
Unit filling
WARNING: Do not switch on the equipment when it is not filled with water as it will seriously damage the electric
heating element. (Failure to comply with this instruction will invalidate your warranty)
To fill the equipment you need to:
The tap present in the hydraulic unit must be put in the open position, the opening of the tap allows the
equipment’s supply. The retain system incorporated in the safety hydraulic unit prevents from the heat water
return.
open the main water supply or the equipment water supply cock;
open a hot water tap (e.g. bathroom, wash basin, etc.) to allow the water to flow out; when the water outflow
from the tap is constant the equipment will be full;
check that there are no leaks from the various hydraulic connections;
We recommend that you clean the pipes before laying them.
Only proceed with the electrical connection after performing this operation
4.7
Unit emptying
Should the unit be going to remain unused for a prolonged time, we recommend that you empty it. In this case proceed
as follows:
Turn off the power supply and the main water supply;
open a hot water tap to allow air to flow in;
verify that the discharge connector of the hydraulic safety unit is connected to a drain as specified in par. 3.1.1.
turn the emptying knob on the hydraulic safety unit to the open position;
4.8
Long period without use
When the unit is restarted after a long term period, you should flush and cleanse the system thoroughly before usage.
Open each tap until the water is clean.
5
USAGE INSTRUCTIONS
CAUTION! The equipment is not intended to be used by any persons ( including children) having reduced sensory
or mental faculties, or lacking experience or knowledge, unless they are under the supervision of a person in
charge of their safety, or they are capable of receiving proper instructions regarding equipment usage.
Children must be watched to ensure that they don't play with the equipment.
5.1
Switch-on
WARNING: Before switching on the equipment, always verify the polarity correctness of the electrical connection;
also check that the water heater is filled with water, to avoid seriously damaging the electric heating element.
The appliance has an adjustment thermostat that automatically controls the water temperature; the indicator light stays
on only during the heating phase
5.2
Dripping from water safety unit.
With heating, the water expands and cannot be compressed. If the plumbing system is unable to absorb this increased
volume the internal pressure increases, causing intervention of the safety device to operate by discharging the excess
water and preventing overpressure in the tank.
5.3
Temperature adjustment
IMPORTANT:
The adjustable thermostat allows power consumption to be optimized according to the comfort
required (hot water temperature). However, in order to prevent “legionella” bacteria to form it is advisable not to
allow the stored water temperature to become too low. Therefore, comply with the following general prevention
measures: