Gio Pelle, Inc. is committed to designing safe, reliable, easy-to-operate products that promote greater productivity while 

reducing costs. These systems will provide modern efficient methods of meeting industry needs. To prevent injury, only 

personnel trained in this machines proper operation should use this equipment. Always observe the safety precautions 

listed in this manual and all other warning or safety labels on the machine, when installing, operating and servicing this 

equipment.

In preparing these instructions, we have attempted to recommend the most effective methods and cautions to warn against 

actions that could cause personal injury or make the equipment unsafe. It is important to understand that Gio Pelle, 

Inc. cannot anticipate or list all conceivable methods and warn of all possible hazards. Read this manual thoroughly to 

understand all safety precautions before proceeding to install, operate or service this equipment. The operator’s setting 

of the machine and proper use of the wand solely determines the severity and success of the treatment. Always try the 

operation of the unit on a sample patch of your own skin first. This not only helps you to determine the capabilities 

but also gives you a clearer understanding of what the patient feels. Let their responses guide you in providing a safe, 

satisfying application.

Occupational Exposure to Bloodborne Pathogens

During a treatment, the abrasive powder becomes contaminated with particles of skin, tissue, oil and possibly body 

fluids. On December 6, 1991, the Occupational Safety and Health Administration (OSHA) promulgated the Occupational 

Exposure to Bloodborne Pathogens Standard 29 CFR 1910.1030. Contact OSHA, local and state authorities to determine 

if the collected waste powder is considered biological substance that may have particular requirements for disposal.

Breathing & Eye Protection, Clothing & Other Apparel

During a treatment, it is mandatory for the operator to wear rubber gloves, facemask and eye protection. Read the Material 

Safety Data Sheet in the back of the manual to understand the nature and proper use of the abrasive media. Due to the 

machine’s quietness, hearing protection is not required.

Additional Safety Information

• 

American National Standards Institute (ANSI)

  1430 Broadway

  New York, NY 10018
• 

Federal Drug Administration (FDA)

  Rockville, MD 20857

  1-888-463-6332

  http://www.fda.gov
• 

National Institute for Occupational Safety & Health (NIOSH)

  http://www.cdc.gov/niosh/homepage.html
• 

National Safety Council

  444 N. Michigan Ave.

  Chicago, IL 60611
• 

U.S. Department of Labor

  Occupational Safety & Health Administration (OSHA)

  200 Constitution Ave.

  Washington, D.C. 20210

  (202) 693-1999

  http://www.osha.gov

Содержание GP-PL-70

Страница 1: ...peration Maintenance Manual Gio Peel Microdermabrader Model GP PL 70 7740 Records Street Indianapolis IN 46226 317 545 6196 800 428 1610 Fax 317 543 3289 www giopelle com LGPMANUALVER02 11 3 11 M I C R O D E R M A B R A D E R ...

Страница 2: ...tion with skin lighteners Overall rejuvenation of skin health Enhanced penetration of carefully chosen topical actives after treatment Elimination of potential for adverse chemical irritation May be performed during pregnancy May be performed shortly after surgery using appropriate adjustment of vacuum and or crystal flow May assist in healing due to increased blood flow Hyperpigmentation risks ar...

Страница 3: ...to medium depth uniform abrasion of the epidermis Microdermabrasion is a buzzword in the field of skin care introduced to the United States in 1997 European esthe ticians began using microdermabrasion in the 1980 s Microdermabrasion expands the number of therapy options available in your office which reinforces your reputation in the local market and expands your patient base ...

Страница 4: ...abetes Skin Cancer Auto Immune Disease Vitiligo Telangiectasias Cystic acne should be treated medically and brought under control prior to microdermabrasion Treating telangiectasias should be determined by the severity of the condition We do not believe this condi tion can be corrected with microdermabrasion there fore vasodilatation disorders should be treated before attempting microdermabrasion ...

Страница 5: ...provements in machines and machine specifications which it considers necessary and does not assume any obligation to make these said changes in machines and equipment previously sold The information in this document is subject o change without notice and does not represent a commitment on the part of Gio Pelle Inc No part of this document may be reproduced or transmitted in any form or by any mean...

Страница 6: ...s of our product YES NO 2 What factors influenced your decision to buy this equipment circle all that apply Features Price Delivery Functions Simplicity Reputation Other explain 3 How could we improve the literature 4 Give us your overall impression of the clarity understanding and effectiveness of this manual 5 Pick out 2 items in the manual and tell us how we could improve them 1 2 6 Did the pro...

Страница 7: ...ives you a clearer understanding of what the patient feels Let their responses guide you in providing a safe satisfying application Occupational Exposure to Bloodborne Pathogens During a treatment the abrasive powder becomes contaminated with particles of skin tissue oil and possibly body fluids On December 6 1991 the Occupational Safety and HealthAdministration OSHA promulgated the Occupational E...

Страница 8: ... flow control valve How To Get The Most From This Manual Properly follow the instructions in the order listed below to avoid injuries or jeopardize any warranty coverage Use this manual as a check off list Check mark each task when completed Concentrate on the material pre read the manual first before doing anything else Read in an isolated area away from distractions Do it our way first We ve spe...

Страница 9: ...s Contact us immediately at 800 428 1610 if there are any items missing or there is any indication of a problem 1 Gio Peel Microdermabrader 2 Crystal Capsules 3 Filter 4 Clear Filter Cover 5 Vacuum Port Cover Figure 1 1 2 3 4 5 6 Inspection Checklist Verify the items shown in figure 1 are included with your Gio Peel Microdermabrader 7 6 Twin Line Disposable Tubing 7 Reusable Nozzles blue 8 Disposa...

Страница 10: ...keep Crystal Capsule secured in upright position 06 External Filter Cover Prevents crystal from getting into motor ports causing damage WARNING Neverattempt to lift the machine by the filter assemblies 07 Main Power Switch Turns unit on 08 Power Receptacle Connects power cord to machine 09 Carrying Handle For easy portability 10 Cooling Fans Located on back of the unit Keeps the motor running cool...

Страница 11: ...rings down inside the opening in the capsule Turning the Unit On Place the master power switch on the side of the unit in the OFF position Plug the POWER CORD into the connector located on the back of the microdermabrader Attach the other end of the POWER CORD to a properly grounded outlet supplying 115vac Depress the I portion of the master power switch located on the back of the Gio Peel to turn...

Страница 12: ...ugh the tubing to the nozzle The specially engineered nozzle allows for uniform steady and effective abrading action Once the abrading media is passed over the skin it is drawn away and suctioned back into the bottom half of the sealed waste receptacle portion of the Crystal Capsule Crystal emission should be activated only when the nozzle is in full immediate contact with the treatment area Immed...

Страница 13: ...s no Aluminum We offer a variety of three crystal sizes that allow you to customize your treatment for the needs of your patient Normal 12 Developed for all skin types Great for general polishing of the skin Also used for sensitive skin and older thin skinned patients that bruise easily Aggressive 10 Used on most skin types except for sensitive skin You can start the patient with NORMAL 12 and inc...

Страница 14: ...ntact with the patient tubing may be used multiple times before changing Requires Disposable Crystal Free Tips and GP DCFT HP Handpiece GP IM CAN 2 Disposable Waste Canister For use with disposable and resusable crystal free tips Waste is suctioned inot self contained canister and can be used sealed with rubber lid for disposal Requires Crystal Free Tips and GP DCFT HP D or GP DCFT HPS Handpiece a...

Страница 15: ... 5 Drape patient s hair and clothing 6 Evaluate the skin to determine the appropriate crystal size for the treatment If you are unsure how the patient will tolerate treatment always start with NORMAL 12 You can always progress to a more aggressive crystal 7 Start by cleansing the skin with Chamomile Cleanser 8 The skin must be completely dry before the procedure is conducted 9 With gloves on test ...

Страница 16: ...actice Repeat in three different directions 5 Next continue with the upper lip area the chin and any remaining areas on the side of the face Repeat in three different directions 6 Repeat above steps on the opposite side of the face 7 Lower the suction to about level 10 and perform the treatment on the neck Run the handpiece in an upward motion then pull and lift outward toward the ears Two passes ...

Страница 17: ...h a new or clean GP AHP 1B Reusable Nozzle Never reuse a nozzle on different patients If using one of the Disposable Crystal Free Nozzles please dispose of according to local state and federal guidelines 2 If using GP RT5 Reusable Tubing you may reuse it without cleaning unless it has been contaminated or has come in direct contact with the patient Tubing should be replaced when worn out 3 Wipe an...

Страница 18: ...ore than the use of topical products Q Can you treat cystic acne with the Gio Peel A Cystic acne should be treated with an oral or topical antibiotic prior to beginning microdermabra sion treatments The physician should determine when treatment can begin Q Should a patient with Rosacea receive treatments A Active Rosacea should never be treated If the condition is calm the patient can be treated a...

Страница 19: ...cne scars Blackheads and comedones Age spots superficial pigmentation Adjunct therapy to cosmetic surgery Blending post lasered skin Treatment Pre treatment Recommendations The quality of results of any dermatological procedure depends on a thorough understanding of the skin history and previous treatments Assessment of the problem and current skin condition should be followed by a treatment plan ...

Страница 20: ...Nut will increase or decrease the crystal flow clockwise tight maximum crystal flow counter clockwise less crystal flow Eye Ear Hair Protection The patient s hair should be covered with a disposable cap that covers the ears to protect them from crystals The patient should remove contact lenses and eyeglasses The eyes MUST be protected with eye patches cotton balls goggles tanning eyecups or a comb...

Страница 21: ...up excessive abrading material Any abrading material left in the supply line will be sucked out within seconds of pulling the tubing off the Crystal Port and placing the nozzle against the skin Post Treatment Recommendations Some patients may experience a minor temporary reddening of the skin similar to a mild sunburn or windburn Hydration should be maintained externally and internally Patients sh...

Страница 22: ...le either continue the treatment or adjust the suction level accordingly Repeat this action until you have covered that half of the forehead Then repeat this action in three different directions Continue from the temples down the side of the face and cheek area Again repeat this motion in three different directions Sweep across the cheeks to the nose avoiding the under eye area The nose can be a d...

Страница 23: ... cleaning A mild disinfectant cleaner can be used to clean the outside of the machine DO NOT CLEAN ANY PART OF THE MACHINE WITH ALCOHOL DO NOT spray cleaner directly onto the machine Place Vacuum Post Cover onto Vacuum Port when Crystal Capsule is not installed or when storing fig 20 Crystal Capsule Care and Storage Carefully pull the Crystal Capsule off of the machine s Vacuum Post Cover the two ...

Страница 24: ... fuses inside the power cord receptacle need replacing or the circuit breaker of the outlet needs to be reset Vacuum pressure seems low Check to see if the Crystal Capsule is securely in place and pushed onto the vacuum post fully see page 7 Remove the Crystal Capsule and inspect the vacuum port post o rings for any dam age If damaged carefully cut off the defective o rings and install two new o r...

Страница 25: ...uct of its kind sold anywhere Each particle is rough blocky and manufactured in a way that produces very sharp edges It is this physical structure that provide such improved performance when the equipment is used properly during microdermabrasion Additional supplies are available from your dealer Aluminum Oxide Crystals GP IM CAP 90 Fast Cut GP IM CAP 100 Aggressive GP IM CAP 120 Normal Completely...

Страница 26: ...gs 10 per pkg GP IM SEA 1 Filter Canister O Ring 6 per pkg Item No Product Price TOTAL Qty Order No Date of order GIO PELLE ORDER FORM Sales Rep Initial Order Yes No Gio Pelle Special Instructions Sub Total Sub Total TOTAL Account No Customer P O Attn SHIPPING CHARGE INFORMATION Shipping charges are prepaid by Gio Pelle and added to customers bill SALES TAX INFORMATION Indiana customers add 6 sale...

Страница 27: ...er GIO PELLE ORDER FORM Sales Rep Initial Order Yes No Gio Pelle 7740 Records St Indianapolis IN 46226 317 545 6196 800 428 1610 Fax 317 543 3289 www giopelle com LGPM01 04 09 Special Instructions Sub Total Sub Total TOTAL Account No Customer P O Attn SHIPPING CHARGE INFORMATION Shipping charges are prepaid by Gio Pelle and added to customers bill SALES TAX INFORMATION Indiana customers add 6 sale...

Страница 28: ...th these convenient tri fold bro chures Full color on a glossy card stock Size 81 2 x 311 16 50 per bag Poster Item No GP MP Our full color microdermabrasion poster is an effective way to ad vertise inside the office Mounted on durable foam core board and includes an easel Size 11 x 17 Face Eye Mask Gel Packs Item No GP GELPK FACE Item No GP GELPK EYE Acloth surface provides a thermal barrier Easi...

Страница 29: ...This product contains no Aluminum Average Chemical Analysis Al2 O3 99 55 TiO2 0 01 SiO2 0 05 Fe2 O33 0 04 CaO3 0 03 MgO 0 02 Alkalis 0 30 Average Physical Properties Crystallography Alpha alumina crystallized mineral Chemical Nature Amphoteric True Specific Gravity 3 95 Gms cc Moisture Content 0 5 maximum Knoop 100 Hardness 2000 Moh s 9 0 Melting Point 2000 C approximately Shape Blocky very sharp ...

Страница 30: ...certify operators may void equipment warranty Business Address City State Zip Country Phone Fax E mail Date Purchased Purchased From Model Number Serial Number Warranty Registration Operator Training Certification Date Name Title Signature THE FOLLOWING OPERATORS HAVE READ AND UNDERSTOOD THE GIO PEEL OPERATING MANUALAND HAVE RECEIVED HANDS ON TRAINING IN THE PROPER USE AND MAINTENANCE OF THE SPECI...

Страница 31: ...a limited period of time Call Gio Pelle at 1 800 428 1610 for details To obtain service under this warranty the original purchaser must obtain prior approval and a Return Goods Authorization Number RGA Num ber All equipment returned for repair or replacement must be shipped pre paid to Gio Pelle Inc This warranty may be declared null and void upon Gio Pelle s sole dis cretion and determination of ...

Отзывы: