GIMA WARRANTY CONDITIONS

Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the 

material and the production. The warranty is valid for 12 months from the date of supply of GIMA.

During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to 

production reasons. Labor costs and personnel traveling expenses and packaging not included. All components subject 

to wear are not included in the warranty. 

The repair or replacement performed during the warranty period shall not extend the warranty.

The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare 

parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic 

devices or software due to outside agents such as: voltage changes, electro-magnetic fields, radio interferences, etc. 

The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed, 

cancelled or changed. The defected products must be returned only to the dealer the product was purchased from. 

Products sent to GIMA will be rejected.

Appendix

General Knowledge of ECG

Normal sinus rhythm

: In sinus conditions, S 

heart rate is in the range of 60 to 100 times 

per minute and the rhythm is regular. P wave is 

normal and each one is followed by a QRS wave. 

P-R interval: 0.12~0.20s;

QRS wave: 0.06~0.10s; No ectopic ECG activity. 

Symptom: Sinus rhythm, heart rate: 60~100bpm

Indication: Normal

Several abnormal ECG waveforms

1) 

Tachycardia

: The heartbeat becomes faster. 

Tachycardia is determined by the rhythm of the 

heart, the average rhythm beats faster than 100 

times a minute is considered as Tachycardia. The 

result description “Suspected fast beat” in this 

device may be doubted as Tachycardia.

Symptom

: heart rate>100bpm

Indication

: It may occur with the normal people 

who have these physiology

conditions: rage, fatigue, smoking, drinking too 

much wine, excessive coffee and strong tea, etc.

Pathology

: anemia, Hyperthyroidism, blood 

hypoxia, myocarditis, hypokalemia, fever, influence of some medication (such as atropine, epinephrine etc.).

Suggestion: If it belongs to pathology condition, please go to hospital.

2) 

Bradycardia

: The heartbeat becomes more 

slowly. It is determined by the rhythm of the heart, 

the average rhythm is less than 60 beats per 

minute is considered as Bradycardia. The result 

description “Suspected slow beat” in this device 

may be doubted as Bradycardia.

Symptom

: heart rate<60bpm

Indication

: It occurs when healthy people fall 

asleep, and it can be found in athlete (or those 

who love doing sports frequently), old people, 

or vagus excitement person. 

Pathology

: Sick sinus syndrome, Ischemic heart disease,Cardiomyopathy, intracranial hypertension, increased hypokalemia, 

Low temperature, period of convalescence of acute infectious disease or after use some medicines such as digitalis.

Suggestion: If it belongs to the pathology condition, please see the doctor.

3) 

Premature beat

: In a normal beat a QRS waveform appears prematurely and is followed by a comeback pause. The result 

description “Suspected occasional short beat interval” in this device may be doubted as Premature beat.

What is premature beats?It is premature contraction. The normal heart beat is always regularly, and each beat interval 

is also symmetrically; Premature beat is out of his general regulation, the heart beats prematurely and followed by a 

long time interval; the phenomena of a premature beat between two heart beats is called inserting premature beat. The 

display of “early beat” may be suspected Premature beat.

According to different original positions it can be divided into Premature Atrial Contraction,

ENGLISH

Figure 1 Normal ECG Waveform

Figure 2 Tachycardia Waveform

Figure 3 Bradycardia Waveform

Содержание 33259

Страница 1: ...ATTENTION The operators must carefully read and completely understand the present manual before using the product AVIS Les opérateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATENCIÓN Los operadores tienen que leer y entender completamente este manual antes de utilizar el producto Manuale d uso User manual Manuel de l utilisateur Guía de uso Shenzhen Creative Industry ...

Страница 2: ... device is not equipped with detachable parts the user should NOT take its shell apart without permission 13 All the parts of the monitor should NOT be replaced at will If necessary please use the components provided by the manufacturer or those that are of the same model and standards as the accessories along with the monitor which are provided by the same factory otherwise negative effects conce...

Страница 3: ...licable for use in clinics and homes and convenient to operate by the patients themselves The device is not an ECG monitor as used in clinical institution or hospital but is used for spot check purpose ONLY It can not be used to substitute the normal ECG examination or real time monitoring The measurement results are a useful reference for doctor but do not make direct diagnostic or analytical dec...

Страница 4: ...interference Hold the device with the right hand Make sure that the palm and fingers touch the metal electrode I and II reliably Place the electrode III on bare skin about 5cm below the left nipple The ECG signal detected by Chest Measurement is similar to Lead V ECG signal Possible improper operation A The contact place of electrode III deviates from left chest B The holding gesture is incorrect ...

Страница 5: ...e Lead I and Lead III ECG signal according to the following table to connect the lead wires to the electrodes Possible improper operation A Wrong in connecting lead port B Place the electrode in the wrong part of your body Electrode Lead Location Lead I Lead II Lead III The intersection between the centerline of the right clavicle and Rib 2 RA RA LA The intersection between the centerline of the l...

Страница 6: ...in Figure 3 6 The device will return to the main screen automatically after the data is saved 4 If the wireless transmission is selected the device will go to the screen as shown in Figure 3 7 after the data is saved Press the Send key on the device side to start transmitting ECG record wirelessly and on the host side the Wireless Receive icon should be clicked while running software ECG Viewer Ma...

Страница 7: ...Figure 3 10 Meanwhile from now on it won t store the new record until the user manually deletes the unnecessary data or upload the records to PC to free some memory 5 The device will power off automatically if there is no any key operation or signal inputting for a while 3 4 Wave Review 3 4 1 Operation Description 1 Select Review on main menu screen then press OK button the device enters record li...

Страница 8: ... on the host side click the Wireless Receive icon while running the software ECG Viewer Manager on PC the data will be transmitted and saved on PC 4 Select YES then press OK button to perform deletion and return to record list screen Press Return button directly this record will not be deleted and the screen will return to record list screen 3 4 2 Measurement Result Description When device detects...

Страница 9: ...t 3 Suspected fast beat 4 Suspected short run of fast beat 5 Suspected a little slow beat 6 Suspected slow beat 7 Suspected occasional short beat interval 8 Suspected irregular beat interval 9 Suspected fast beat with short beat 10 Suspected slow beat with short beat interval 11 Suspected slow beat with irregular beat interval ENGLISH ...

Страница 10: ...ted on the screen as shown in Figure 3 19 If choose YES and press OK button all the records will be deleted as shown in Figure 3 20 Note The operation of data deletion carried out in the memory screen means all the data in the device will be deleted if you only want to delete one record please do that on waveform review screen 3 5 2 Upload Data Connect the device to PC with USB data cable the devi...

Страница 11: ...brightness with Navigation Key 1 7 level adjustable 3 Press OK button to save setting and return to the upper level menu screen 3 6 4 Beeper Setting 1 On system setting screen select Beeper to enter beeper setting screen as shown in Figure 3 27 2 Choose ON or OFF with Navigation Key to turn on the beeper or turn off the beeper the default setting is ON 3 Press OK button to save setting and return ...

Страница 12: ...to download 1 On the App Store of the device enter Shenzhen Creative into the search line Note if you use an iPad to search please select iPhone only when searching 2 Once the search results are listed select the result with health icon then download the corresponding APP software Instruction for Measurement Make sure the APP software is successful to connect with the Easy ECG Monitor Refer to the...

Страница 13: ...ainst harmful ingress of liquid Ordinary equipment without protection against ingress of liquid Electro magnetic Compatibility Group I Class B 4 4 Display LCD type colour LCD Display area 57 6mm 40mm 4 5 Data Memory Up to 10 hour records can be saved in the built in memory Stored data records can be uploaded to the computer by data cable provided by the manufacturer 4 6 Overall Dimension and Weigh...

Страница 14: ...ll batteries 3 Please contact the local service center Possible Reason 1 The batteries are drained or almost drained 2 The batteries are not inserted properly 3 The device is broken out Trouble The device is failure in measuring heart rate Solution 1 Place the electrode correctly 2 When measuring please keep quiet and avoid moving 3 Keep away from interference source 4 Change a place chest to meas...

Страница 15: ...bol on the label indicates the separate collection of electrical and electronic equipment Caution The wrong disposal of electric and electronic equipment may involve sanctions ENGLISH Note The symbols and are displayed on the screen the others are marked on the device panel Symbol Description Symbol Description Heart Rate Unit beats per minutes Caution read instructions warnings carefully Measure ...

Страница 16: ...beat in this device may be doubted as Tachycardia Symptom heart rate 100bpm Indication It may occur with the normal people who have these physiology conditions rage fatigue smoking drinking too much wine excessive coffee and strong tea etc Pathology anemia Hyperthyroidism blood hypoxia myocarditis hypokalemia fever influence of some medication such as atropine epinephrine etc Suggestion If it belo...

Страница 17: ...remature beat Indication PVC occurs frequently Suggestion Please see the doctor The result description Suspected irregular beat interval in this device may be doubted as Bigeminy or Trigeminy 6 Short run of tachycardia PVC Premature Ventricular Contraction occurs more than 3 times continuously Testee s Symptom PVC occurs More than 3 times continuously The heart beat is fast and regularly but start...

Отзывы: