Packaging
4.3
Whilst the MetStream 105 is being moved to its installation site, the unit should be kept in
its packaging. Retain the packaging for use if the unit has to be moved or returned to Gill
Instruments.
Installation requirements
4.4
4.4.1
Host system
Select from the following:
Router with Ethernet input.
Or Wi Fi Modem with Ethernet input.
Or LAN Ethernet input.
Plus PC with Wi Fi or Ethernet input to view MetStream Data.
Internet Browser (we recommend Firefox, Chrome or IE9.0 or later)
Optional USB 2.0/3.0 data stick to export store logged data.
Gill Instruments MetPak Range Unit set for ASCII, RS232, RS 422 output (see
http://www.gillinstruments.com/products/anemometer/weather-station-range.htm
for the range of MetPak units).
4.4.2
Software
Gill MScan Software to detect the MetStream IP address.
o
Note MScan app works on Windows devices.
4.4.3
Cables
To connect MetStream to the host unit (e.g. MetStream 105 to a MetPak
unit).
Use a suitable RS232 or RS422/485 cable, there are restrictions on cable type and
length for suitable operation, refer to the connecting equipment Manual.
To connect the MetStream 105 to an Ethernet port.
Use a CAT 5 CAT5e or CAT 6 cable to connect between the MetStream 105 and
the user interface equipment.
Ethernet cables of up to 100 metres can be supported.
A 2 Metre Ethernet test cable is supplied (non-crossover type).
To connect the MetStream 105 directly to a PC.
Use a CAT 5 CAT5e or CAT 6 crossover cable to connect between the MetStream
105 and the PC Ethernet port.
Ethernet cables of up to 100 metres can be supported.
A 1 Metre Ethernet crossover test cable is supplied.
To connect DC power to the MetStream unit
A 12v dc power supply and lead with wired connector are supplied otherwise use a
cable suitable for connecting a dc supply of nominally 12v dc (1 amp
recommended). If requiring full current then take into account volt drops if a long
cable run is needed.
Alternatively a 2.1mm, 12v dc plug is provided if it is required to connect to a user
12v dc power supply to MetStream.