Safety
•
Maintain a minimum clearance of 14” (355.6mm) between the hood outlet and the ceiling or any
obstruction above the hood.
18” (457.2mm) is recommended for best performance
.
•
Exercise care when lifting or moving the unit. See Section 1-4.4 for Hood weights.
•
Exercise care when removing the wooden crate from around the unit.
!
CAUTION
•
DO NOT
operate the unit unless you fully understand the components and their intended function.
•
Be careful not to bend the fins or break the ionizer wires on the Electrostatic Air Cleaner (EAC). Doing
so will prevent the EAC from working properly and cause a shutdown of power to the appliance being
used with the hood.
•
Failure to comply with these
CAUTION
notices may result in minor or moderate injury, equip-
ment/property damage, and void the warranty.
!
CAUTION
•
The electronic components of the Control Panel are impact-sensitive. Exercise care around the Control
Panel to maintain proper operation.
•
Do not attempt to dry the EAC after cleaning by installing it and running the hood to force air dry or by
running an appliance below to heat dry. This could potentially damage the EAC system leading to fail-
ure and voiding the warranty. The filter must air dry at ambient room temperature, preferably overnight.
•
During cleaning of Hood.
••
DO NOT
steam clean.
••
DO NOT
use products containing chlorine.
••
DO NOT
use abrasive products, steel wool or scouring pads.
•
Failure to comply with these
CAUTION
notices may result in equipment/property damage and void the
warranty.
CAUTION
Содержание FSH-3.5
Страница 2: ......
Страница 4: ......
Страница 18: ...8 Model FSH 3 5 FSH 4 Installation 2 03 3 Hood Mounting Detail Free Standing STEP 1 STEP 2 ...
Страница 24: ...14 Model FSH 3 5 FSH 4 Installation 2 05 2 Routing Power Wires 2 05 3 Hood and Appliance Interlock Diagram ...
Страница 28: ...18 Model FSH 3 5 FSH 4 Installation NOTES ...
Страница 30: ...Model FSH 3 5 FSH 4 Overview 20 3 01 Control Panel 7 6 5 4 2 1 ILS Only 6 5 4 3 8 10 9 ...
Страница 36: ...26 Model FSH 3 5 FSH 4 Overview Notes ...
Страница 48: ...38 Model FSH 5 FSH 6 Operation Filter Maintenance Notes ...
Страница 52: ...42 Model FSH 3 5 FSH 4 Hood Cleaning and Maintenance Notes ...
Страница 56: ...46 Model FSH 3 5 FSH 4 Parts List 7 2 Component Drawer FSH 3 5 FSH 4 ILS Only 5 10 7 3 2 1 9 11 8 6 4 12 13 14 ...
Страница 60: ...50 Model FSH 3 5 FSH 4 Parts List 7 4 Baffle Filters and Switches 2 1 Not shown 3 4 5 ...
Страница 62: ...52 Model FSH 3 5 FSH 4 Parts List 7 5 Doors and Front Panel Ceiling Mount Not shown 3 4 2 6 1 1 5 8 9 10 ...
Страница 66: ...56 Model FSH 3 5 FSH 4 Parts List Notes ...
Страница 67: ...Model FSH 3 5 FSH 4 ...