![Gilera 633721 Скачать руководство пользователя страница 283](http://html.mh-extra.com/html/gilera/633721/633721_workshop-manual_2227191283.webp)
YES go to 16 NO go to 15
15
- Check cable harness and connectors more carefully.
16
- Connect the control unit connector.
Set the switch to «
ON
» with switch to «
RUN
» and side stand raised. Repeat the «
ON
» «
OFF
» «
ON
»
switching.
Check the presence of voltage pulses on the Stepper command lines.
Set-up for direct voltage measurements.
N.B.
PULSES ARE USED TO CHANGE THE STEPPER POSITION.
Electric characteristic
14-24 =
V (pulses for a few seconds)
6-21 =
V (pulses for a few seconds)
After reaching the optimum position, the power
supply voltage becomes null.
YES go to 17 NO go to 18
17
- The Stepper circuit is efficient.
18
- Check the control unit connector. Replace the control unit, if necessary.
Lambda probe
SIGNAL CHECK
Nexus 500 euro 3
Injection
INJEC - 283
Содержание 633721
Страница 1: ...WORKSHOP MANUAL 633721 633728 Nexus 500 euro 3 ...
Страница 4: ......
Страница 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 18: ...INDEX OF TOPICS TOOLING TOOL ...
Страница 30: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 43: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 78: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 82: ...INDEX OF TOPICS ENGINE ENG ...
Страница 190: ...Oil pump cover screws 0 7 0 9 Engine Nexus 500 euro 3 ENG 190 ...
Страница 191: ...INDEX OF TOPICS INJECTION INJEC ...
Страница 289: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 308: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 327: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Страница 337: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 358: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Страница 362: ...INDEX OF TOPICS TIME TIME ...
Страница 407: ...Technical Data Transmission 9 83 99 375 Turn indicators 54 Tyres 10 ...