Capricorn PLUS Installation Note
2
DCP0000273(B)
C
AUTION
I
N ORDER TO PREVENT DAMAGE TO THE
RF
C
ONNECTORS
,
SECURE THE CABLES TO A PERMANENT
,
STATIC
OBJECT SUCH AS A TABLE OR PIPE
,
AT A DISTANCE OF
25-60
CM
(10-25
IN
.)
FROM THE
CPE,
PRIOR TO
CONNECTION
.
Connecting RF Cables
Connect the two RF cables (from the LNB and ODU) to the RF-IN and RF-OUT connectors, respectively, as shown
below, using a recommended torque of 13 lb*ft/in (1.5 N/m).
Connecting LAN Cable
Use only CAT-5 type cables (approved by Gilat) to connect to the LAN ports.
Use only the LAN LEDs indications to make sure that the LAN ports are operational.
Connecting Grounding Cable
Connect the grounding cable (GND) from the CPE to the approved site.
Connecting Power Cable
Warning
TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL POWER CORDS BEFORE
SERVICING THE UNIT.
The Capricorn
PLUS
CPE is powered with a 48VDC external power source. The CPE power connection
uses the optionally supplied Gilat power cables (CB000912) that include a 7A fuse on the “+” wire. An
accessible two pole circuit breaker (Rated 10A) must be provided in the building for the DC power feed
source In case of dual power supplies connect both inputs to the relevant power sources.
Figure 1: Capricorn PLUS CPE Cables
Warning
P
LEASE NOTE THAT SETTING THE VOLTAGE TO A DIFFERENT SETTING WILL CAUSE CRITICAL DAMAGE TO THE
OUTDOOR
U
NIT
.