Capricorn PLUS Installation Note 

 

 

DCP0000273(B) 

 

 

 

C

AUTION

 

I

N ORDER TO PREVENT DAMAGE TO THE 

RF

 

C

ONNECTORS

,

 SECURE THE CABLES TO A PERMANENT

,

 STATIC 

OBJECT SUCH AS A TABLE OR PIPE

,

 AT A DISTANCE OF 

25-60

 CM 

(10-25

 IN

.)

 FROM THE 

CPE,

 PRIOR TO 

CONNECTION

.

 

 

 

Connecting RF Cables

 

Connect the two RF cables (from the LNB and ODU) to the RF-IN and RF-OUT connectors, respectively, as shown 

below, using a recommended torque of 13 lb*ft/in (1.5 N/m). 

 

Connecting LAN Cable

 

Use only CAT-5 type cables (approved by Gilat) to connect to the LAN ports.  

Use only the LAN LEDs indications to make sure that the LAN ports are operational. 

 

Connecting Grounding Cable 

Connect the grounding cable (GND) from the CPE to the approved site. 

 

Connecting Power Cable

 

  

 

Warning 

TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL POWER CORDS BEFORE 

SERVICING THE UNIT.

 

 

The Capricorn 

PLUS 

CPE is powered with a 48VDC external power source. The CPE power connection 

uses the optionally supplied Gilat power cables (CB000912) that include a 7A fuse on the “+” wire. An 

accessible two pole circuit breaker (Rated 10A) must be provided in the building for the DC power feed 

source In case of dual power supplies connect both inputs to the relevant power sources.

 

 

Figure 1: Capricorn PLUS CPE Cables 

 

  

 

Warning 

P

LEASE NOTE THAT SETTING THE VOLTAGE TO A DIFFERENT SETTING WILL CAUSE CRITICAL DAMAGE TO THE 

OUTDOOR

 

U

NIT

.

 

 

Содержание SkyEdge II-c Capricorn PLUS

Страница 1: ...ical Support CAUTION THE CPE MUST BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END OF THE GROUNDING CABLE TO THE GROUNDING STUD ON THE REAR OF THE CPE AND THE OTHER END TO THE SITE MAIN GROUND CONNECTION 18AWG GROUNDING CABLE SHOULD BE USED THE CPE MUST BE CONFIGURED PRIOR TO ATTACHING THE RF CABLES THE POWER CABLE MUST BE DISCONNECTED FROM THE CPE PRIOR TO CONNECTING THE RF CABLES General P...

Страница 2: ...the LAN ports are operational Connecting Grounding Cable Connect the grounding cable GND from the CPE to the approved site Connecting Power Cable Warning TO REDUCE THE RISK OF ELECTRIC SHOCK DISCONNECT ALL POWER CORDS BEFORE SERVICING THE UNIT The Capricorn PLUS CPE is powered with a 48VDC external power source The CPE power connection uses the optionally supplied Gilat power cables CB000912 that ...

Страница 3: ... 30dB Symbol Rate 256Ksps Duration 60 second 6 Click Activate The specified frequencies represent the worst case scenario requiring the modem to use lower attenuator values for driving the BUC to maximum output power 7 Measure the BUC output power and then from the webpage click Deactivate to cease transmission of the test signal Ideally the BUC should be powered at least 5 10 minutes prior to tak...

Страница 4: ...TX Out port of the modem and connect the RF cable P N CB052230 Cable RF Type RF Type RG6 LF20cm to the other port of the attenuator If the attenuator has an F Type male connector connect the attenuator directly to the modem If the attenuator has two F Type female connectors use the short cable provided with the modem to connect the attenuator to the modem CAUTION IT IS HIGHLY RECOMMENDED TO POWER ...

Отзывы: