Capricorn PLUS Installation Note 

 

 

DCP0000273(B) 

9.

 

Repeat steps 7 until the output power is less than 0.3dB and higher than the output power in the previous 

measurement (i.e., the last test signal transmitted drove the BUC to near saturation). Record the attenuation value 

used for transmitting the last test signal. 

10.

 

If the attenuation value used for transmitting the last test signal is 11dB or lower, click 

Close

11.

 

If the attenuation value used for transmitting the last test signal is higher than 11dB, install the 10dB attenuator 

(P/N 

RF300927

 - ATT, L-BAND,10dB, N-TYPE F, 50V, 3A,10MHZ passing) provided with the Capricorn 

PLUS modem at the TX Out port of the modem and connect the RF cable (P/N 

CB052230

 - Cable RF Type / RF 

Type RG6 LF20cm) to the other port of the attenuator. 

 

 

If the attenuator has an F-Type male connector, connect the attenuator directly to the modem. If the 

attenuator has two F-Type female connectors, use the short cable provided with the modem to 

connect the attenuator to the modem. 

 

 

C

AUTION

 

I

T IS HIGHLY RECOMMENDED TO POWER OFF THE MODEM WHEN THE 

RF

 CABLE IS DISCONNECTED

,

 UNTIL 

THE INSTALLATION OF THE ATTENUATOR AND THE RECONNECTION OF THE 

RF

 CABLE ARE COMPLETED

 

 

C

AUTION

 

I

F THE MEASUREMENT IS PERFORMED WHEN THE BUC  AMBIENT TEMPERATURE IS LOWER THAN 

10°C

,

 

INSTALL THE ATTENUATOR ONLY IF THE ATTENUATOR VALUE USED FOR TRANSMITTING THE LAST TEST 
SIGNAL IS HIGHER THAN 

12

D

B

 

(

INSTEAD OF 

11

D

B).

 

T

HIS IS COMPENSATE FOR THE TYPICAL HIGHER BUC 

GAIN AT LOWER TEMPERATURES

 

 

Содержание SkyEdge II-c Capricorn PLUS

Страница 1: ...ical Support CAUTION THE CPE MUST BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END OF THE GROUNDING CABLE TO THE GROUNDING STUD ON THE REAR OF THE CPE AND THE OTHER END TO THE SITE MAIN GROUND CONNECTION 18AWG GROUNDING CABLE SHOULD BE USED THE CPE MUST BE CONFIGURED PRIOR TO ATTACHING THE RF CABLES THE POWER CABLE MUST BE DISCONNECTED FROM THE CPE PRIOR TO CONNECTING THE RF CABLES General P...

Страница 2: ...the LAN ports are operational Connecting Grounding Cable Connect the grounding cable GND from the CPE to the approved site Connecting Power Cable Warning TO REDUCE THE RISK OF ELECTRIC SHOCK DISCONNECT ALL POWER CORDS BEFORE SERVICING THE UNIT The Capricorn PLUS CPE is powered with a 48VDC external power source The CPE power connection uses the optionally supplied Gilat power cables CB000912 that ...

Страница 3: ... 30dB Symbol Rate 256Ksps Duration 60 second 6 Click Activate The specified frequencies represent the worst case scenario requiring the modem to use lower attenuator values for driving the BUC to maximum output power 7 Measure the BUC output power and then from the webpage click Deactivate to cease transmission of the test signal Ideally the BUC should be powered at least 5 10 minutes prior to tak...

Страница 4: ...TX Out port of the modem and connect the RF cable P N CB052230 Cable RF Type RF Type RG6 LF20cm to the other port of the attenuator If the attenuator has an F Type male connector connect the attenuator directly to the modem If the attenuator has two F Type female connectors use the short cable provided with the modem to connect the attenuator to the modem CAUTION IT IS HIGHLY RECOMMENDED TO POWER ...

Отзывы: