25
Operating information
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2314-L101-2-7619 / using.fm / 06.02.2012
V
e
rsion 2, 06.0
8
.2010
Resetting to static IP addresses
¤
Press the reset button and hold it for
four
seconds.
¤
Release the reset button.
¤
Press the reset button again for
four
seconds.
¤
Release it again.
The reset is carried out. The IP configuration is now set as follows:
Resetting to dynamic addressing (DHCP)
This allows you to specify that the DECT Manager will automatically receive an IP address
from a DHCP server in the local network.
¤
Press the reset button and hold it for
four
seconds.
¤
Release the reset button.
¤
Press the reset button for
one
second.
¤
Release it again.
¤
Press the reset button again for
four
seconds.
¤
Release it again.
The reset is carried out. The IP configuration is set as follows.
Parameter
Value for the reset
IP address type
Static
IP Address DECT Manager
192.168.143.1
Subnet mask
255.255.0.0
Default Gateway
192.168.1.1
Preferred DNS server, Alternate DNS server
192.168.1.1
Password for access to the Web configurator
admin
VLAN Tagging
Off
Parameter
Value for the reset
IP address type
Obtained automatically
Password for access to the Web configurator
admin
VLAN Tagging
Off