23
Operating information
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2314-L101-2-7619 / using.fm / 06.02.2012
V
e
rsion 2, 06.0
8
.2010
LEDs on the base stations
The Gigaset N720 IP PRO base stations contain two DECT modules with separate status
displays.
Other displays:
u
The second LED from the top (
Power/LAN
) flickers when you are restoring the factory
settings to indicate that the resetting process will begin as soon as you release the
reset button (
From top to bottom
Status of DECT module 1
Power supply status If the power supply is OK, the LED
indicates the LAN connection status.
Status of DECT module 2
Reset button (
Power/LAN 1/2
DECT 1/2
Description
Off
Off
No power supply / No supply voltage
Flashes (once a
second)
Off
The base station is looking for the DECT
Manager
On
Off
Connection established to DECT Manager,
base station service not yet ready
Flashes (every two
seconds)
Off
Firmware is being updated, base station
service not active
On
On
Base station DECT module ready, DECT
synchronised
On
Flashes (every four
seconds)
Base station DECT module ready, DECT not
synchronised
Flashes (every four
seconds)
On
Base station DECT module overloaded, DECT
synchronised
Flashes (every four
seconds)
Flashes (every four
seconds)
Base station DECT module overloaded, DECT
not synchronised
Please note
You can deactivate the base station LED displays using the Web configurator on the
DECT Manager (
DECT 1
Power/LAN
Power/LAN
DECT 2
RESET