System Settings
You can define which types of devices can be served on the subscriber connections in the sys-
tem.
Cordless devices (internal subscriber numbers 1 to 8) are either mobile units or cordless TAE
connections like Gigaset 1000TAE that allow, for example, the connection of telephones and fax
machine cordless to Gigaset 1054isdn. “Mobile unit“ is the default setting for these devices.
For the non cordless devices (internal subscriber numbers 0 and 9) the devices type “telephone“
is the default setting. Modems or fax machines should be connected to 0, and a door opener can
only be connected to connection 9.
w#!o
Press the displayed keys one after
another; enter the
system code
(default
setting 0000).
Each entered number replaces a dash in
the display.
z#=
Press these keys one after another.
The internal subscriber number 0 with
the setting telephone will be displayed
Select the internal subscriber numbers:
z
To search for a subscriber number press
the redial key repeatedly.
The registrated internal subscriber num-
bers with the current settings will be
displayed
Exam; ple: For internal 1 a mobile unit is
setfor internal 0 a modem is set.
Setting the device to be connected:
Possible device types:
Taste
Device type
0
no Function
1
Mobile unit
2
Telephone
3
Modem
4
Fax machine
5
Entrance telephone
6
Neutral
(Telephone and Fax)
=
...
&
Press the number keys to select the
device type, here, for example, a cord
connected connection 0 with fax.
w
Press the save key.