background image

System Hardware Installation

- 32 -

•  Voltages can be present within the server whenever an AC power source is connected. 

This voltage is present even when the main power switch is in the off position. Ensure 
that the system is powered-down and all power sources have been disconnected from the 
server prior to installing a OCP card.

Failure to observe these warnings could result in personal injury or damage to equipment.

Follow these instructions to install the OCP card:

1.  Romove the HDD Cage. See Section 

第 24 第第第3-2-3 Removing Hard Disk Drive Cage (TO22-Z62 

Only)第.

2.  Remove the three screws securing OCP card. 
3.  Lift up the OCP card.
4.  Remove the screw securing OCP card bracket. 
5.  Install the OCP card bracket.
6.  Reverse steps 1 - 4 to install the OCP card into the system.

•  Before installing the OCP card the left PCI-E riser assembly must be first removed, see 

the 「Installing the PCI Expansion Card「 section for instructions on removing the PCI-E 

riser assembly. 

3-8  Replacing and Installing the OCP Card (TO22-Z62 Only)

3

4

2

1

Содержание TO22-Z61

Страница 1: ...TO22 Z61 TO22 Z62 AMD EPYC DP Compute Nodes User Manual Rev 1 0...

Страница 2: ...and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short...

Страница 3: ...uide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any da...

Страница 4: ...icular attention to the plug electrical outlet and the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal sy...

Страница 5: ...stem and discon nect the cables attached to the system before servicing it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives...

Страница 6: ...care to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break CAUTION Risk of explosion if battery is replaced incorrectly or with an in...

Страница 7: ...22 Z62 Only 22 3 2 2 Removing Hard Disk Drive Middle Tray TO22 Z62 Only 23 3 2 3 Removing Hard Disk Drive Cage TO22 Z62 Only 24 3 3 Removing System Cover 25 3 4 Installing the CPU 26 3 5 Removing and...

Страница 8: ...ions 86 5 3 3 UMC Common Options 87 5 3 4 NBIO Common Options 94 5 3 5 FCH Common Options 95 5 4 Chipset Setup Menu 97 5 4 1 North Bridge 98 5 4 2 Error Management 101 5 5 Server Management Menu 102 5...

Страница 9: ...only memory Postcodes 130 5 10 3 S3 Interface Post Code 133 5 10 4 PMU Post Code 133 5 10 5 0xA5XX assigned for AGESA PSP Module 133 5 10 6 0xA9XX 0xAAXX assigned for AGESA NBIO Module 136 5 10 7 0xA...

Страница 10: ...10 This page intentionally left blank...

Страница 11: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Страница 12: ...Low profile half length 1 x OCP mezzanine slot Gen3 x16 occupied by CNVO124 4 x U 2 HBA Video Integrated in Aspeed AST2500 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SD...

Страница 13: ...log Events management platform events trap settings email settings Serial Over LAN vKVM vMedia HTML5 Form Factor Propriety Form Factor 6 5 x 19 4 12 layers PCB Power Power Consumption 480W Max Ambien...

Страница 14: ...CP Mezz 6 x SATAIII SlimLine SAS 10 6GT s 11 7GT s 12 8GT s 4x16 GOP Zen Core Sockets SP3 CPU_0 Board to Board Conn Board to Board Conn M 2 PCIe3 0 x16 2A 2D PCIe3 0 x16 PCIe3 0 x8 PCIe3 0 x16 PCIe3 0...

Страница 15: ...LAN Port x 2 4 Server Management LAN Port 5 System Status LED 6 Power Button 7 ID Button Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs 2 2 Rear View No D...

Страница 16: ...2 System Status LED Green On System is operating normally Amber On Critical condition may indicates System fan failure System temperature Blink Non critical condition may indicates Redundant power mo...

Страница 17: ...Speed LED Yellow On 1Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or rec...

Страница 18: ...LED on Back Panel Disk LED Removed HDD Slot Green ON 1 OFF BLINK 2 BLINK 2 OFF OFF OFF ON OFF ON 1 OFF OFF ON OFF ON Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green OFF OFF Amber Amber OF...

Страница 19: ...er you are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare me...

Страница 20: ...Node into The Shelf Before you install the node into the rack Make sure the system is not turned on or connected to AC power Follow these instructions to install a node into the shelf 1 Install the n...

Страница 21: ...liding it out The tray will not fit back into the bay if inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install the Hard di...

Страница 22: ...back into the bay if inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install the Hard disk drive 1 Remove the System Cover...

Страница 23: ...the drive tray orientation before sliding it out The tray will not fit back into the bay if inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane 1 2 Follow th...

Страница 24: ...drive tray orientation before sliding it out The tray will not fit back into the bay if inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these ins...

Страница 25: ...Make sure the system is not turned on or connected to AC power Follow these instructions to remove the system cover 1 Pull up the latch 2 Slide the cover horizontally to the back and remove the cover...

Страница 26: ...cedures described in the following sections unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws in sequential order 1g2g3 secur...

Страница 27: ...Place the system unit on a flat and stable surface Open the system according to the instructions WARNING Failure to properly turn off the server before you start installing components may cause seri...

Страница 28: ...ent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction DIMM_P0_E0 DIMM_P0_F0 DIMM...

Страница 29: ...rted Table DIMM DIMMs Populated 1R 2 2667 2400 Not Supported 2133 2133 2133 1 1 2 1 1 1 Not Supported Not Supported Not Supported 1 1 1 1 2 4DR 1 2V 2R 2DR 2S2R 2S4R Frequency MT s 2 1 1R 1 package ra...

Страница 30: ...equipment The PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to install the left PCI Expans...

Страница 31: ...31 System Hardware Installation 4 5...

Страница 32: ...o equipment Follow these instructions to install the OCP card 1 Romove the HDD Cage See Section 24 3 2 3 Removing Hard Disk Drive Cage TO22 Z62 Only 2 Remove the three screws securing OCP card 3 Lift...

Страница 33: ...he fan assembly 1 Remove the 4 screws on the top of metal cover 2 Remove the 2 screws at two side of the chassis 3 Lift up the metal cover 4 Remove the supporting sponges 5 Lift up the fan assembly fr...

Страница 34: ...System Hardware Installation 34 3 10 Cable Routing TO22 Z61 HDD Back Plane Board Power Cable Front IO Board Cable HDD Back Plane Board Signal Cable On Board SATA to HDD Back Plane Board Cable...

Страница 35: ...35 System Hardware Installation Busbar Connector Cable NMVe Signal HDD Back Plane Board Cable Top Connector U 2_0 NMVe Signal HDD Back Plane Board Cable Bottom Connector U 2_1...

Страница 36: ...36 System Hardware Installation 3 11 Cable Routing TO22 Z62 HDD Back Plane Board Power Cable Front IO Board Cable HDD Back Plane Board Signal Cable On Board SATA to HDD Back Plane Board Cable...

Страница 37: ...37 System Hardware Installation Busbar Connector Cable OCP Mezzanine Card Cable...

Страница 38: ...38 System Hardware Installation This page intentionally left blank...

Страница 39: ...or CPU0 11 M 2 connector CPU1 12 Function jumper switch 13 System battery 14 Slimline SAS connector 15 Clear CMOS jumper 16 GF_1_1 17 GF_1_2 18 GF_1_3 19 TPM connector 20 Riser slot 1 Gen 3 x1 and x8...

Страница 40: ...Motherboard Components 40 4 2 Jumper Setting 21 21 3 21 3 Clear CMOS CLR_CMOS J1 Enable Default 1 2 3...

Страница 41: ...caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results...

Страница 42: ...gement Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system...

Страница 43: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Страница 44: ...are Version Note Displays BMC firmware version information Onboard LAN Information LAN1 MAC Address Note Displays LAN1 MAC address information LAN2 MAC Address Note Displays LAN2 MAC address informati...

Страница 45: ...IOS Setup 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu s...

Страница 46: ...nfiguration iSCSI Initiator Name Add an Attempt Press Enter for configuration of advanced items Delete Attempts Press Enter for configuration of advanced items Change Attempt Order Press Enter for con...

Страница 47: ...ess Enter to view device firmware version information Device Hardware Configuration Menu Press Enter to configure device and port specific parameters MBA Configuration Menu Press Enter to configure Mu...

Страница 48: ...F Blink LEDs Blink LEDs for a duration up to 15 seconds Default setting is 0 Chip Type Displays the chip type PCI Device ID Displays the PCI device ID Bus Device Function Displays the bus number devic...

Страница 49: ...49 BIOS Setup 5 2 2 1 Firmware Image Menu Main Configuration Page Firmware Image Menu Displays the device s firmware version information...

Страница 50: ...Options available Enabled Disabled Default setting is Enabled Number of VFs per PF Displays the number of VFs per PF in multiple of 8 0 to 64 Max PF MSI X Vectors Displays the maximum number of PF MSI...

Страница 51: ...figuration Page MBA Configuration Menu Configures the Multiple Boot Agent MBA parameters QLogic 577xx 578xx 10 Gb Ethernet BCN57810 Legacy Boot Protocol Selects a non UEFI Boot Protocol to be used Opt...

Страница 52: ...ions available Ctrl S Ctrl B Default setting is Ctrl S Banner Message Timeout Selects the timeout value 0 defaults to 4 seconds 15 is no delay 1 14 is timeout value in seconds Default setting is 5 Lin...

Страница 53: ...CSI boot parameters iSCSI General Parameters Press Enter for configuration of advanced items iSCSI Initiator Parameters Press Enter for configuration of advanced items iSCSI First Target Parameters Pr...

Страница 54: ...t parameters TCP IP Parameters via DHCP Acquires the TCP IP configuration via DHCP Options available Enabled Disabled Default setting is Enabled IP Autoconfiguration Auto configures the IP configurati...

Страница 55: ...ss Enter to configures the DHCP vendor ID up to 32 bytes long Link Up Delay Time Configures the link up to delay time in seconds 0 225 Use TCP Timestamp Enable Disable the TCP timestamp Options availa...

Страница 56: ...n Configuration Page iSCSI Boot Configuration Menu iSCSI Initiator Parameters Configures the iSCSI initiator parameters IP Address Configures initiator IP address Subnet Mask Configures IP subnet mask...

Страница 57: ...ures the second DNS IP address iSCSI Name Configures the iSCSI name CHAP ID Configures the Challenge Handshake Authentication Protocol CHAP ID up to 128 characters in length CHAP Secret Configure the...

Страница 58: ...tion Page iSCSI Boot Configuration Menu iSCSI First Target Second Target arameters Configures the iSCSI first target parameters Connect Enable Disable the target establishment Options available Enable...

Страница 59: ...the target boot LUN number 0 255 iSCSI Name Configures the iSCSI name CHAP ID Configures the Challenge Handshake Authentication Protocol CHAP ID up to 128 characters in length CHAP Secret Configure t...

Страница 60: ...BIOS Setup 60 5 2 3 VLAN Configuration Enter Configuration Menu Press Enter to enter configuration menu for VLAN configuration...

Страница 61: ...or update existing VLAN Configured VLAN List Displays the configured VLAN list information Options available Enabled Disabled Default setting is Disabled Remove VLAN Note Removes the selected VLANs P...

Страница 62: ...CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is E...

Страница 63: ...63 BIOS Setup 5 2 4 1 CPU 0 Information...

Страница 64: ...BIOS Setup 64 5 2 5 SATA Configuration...

Страница 65: ...I ownership change should be claimed by XHCI driver Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Suppor...

Страница 66: ...ec 30 sec 40 sec Default setting is 20 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it i...

Страница 67: ...S Setup 5 2 7 AST2500 Super IO Configuration AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 2 Configuration Press Enter for configuration of advanced...

Страница 68: ...you to configure the Serial port 1 2 settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Devices Settings Note2 D...

Страница 69: ...7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h I...

Страница 70: ...Band Management Windows Emergency Management Services EMS Console Redirection Note Selects a COM port for EMS console redirection EMS console redirection allows the user to configure Console Redirecti...

Страница 71: ...71 BIOS Setup 5 2 8 1 COM1 COM2 Serial Over LAN Legacy Serial Port for Out of Band EMS Console Redirection Settings...

Страница 72: ...edirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Options available 9600 19200 38400 57600 115200 Default...

Страница 73: ...mbo Key Support Enable Disable the VT UTF8 Combo Key Support Options available Enabled Disabled Default setting is Enabled Recorder Mode Note When this mode enabled only texts will be send This is to...

Страница 74: ...S Console Redirection Settings Out of Band Mgmt Port Microsoft Windows Emerency Management Service EMS allows for remote management of a Windows Server OS through a serial port Options available COM1...

Страница 75: ...X Latency Timer Register Options available 32 PCI Bus Clocks 64 PCI Bus Clocks 96 PCI Bus Clocks 128 PCI Bus Clocks 160 PCI Bus Clocks 192 PCI Bus Clocks 224 PCI Bus Clocks 248 PCI Bus Clocks Default...

Страница 76: ...BIOS Setup 76 SR IOV Support If the system has SR IOV capable PCIe devices this item Enable Disable Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Disabled...

Страница 77: ...Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled DIsabled Default setting is Disabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available E...

Страница 78: ...ble the Compatibility Support Module CSM support Options available Enabled Disabled Default setting is Disabled CSM16 Module Version Displays the CSM module version information Please note that this i...

Страница 79: ...lt setting is UEFI and Legacy Please note that this item is configurable when CSM Support is set to Enabled Option ROM execution Network Controls the execution of UEFI and Legacy PXE Option ROM Option...

Страница 80: ...Trusted Computing Configuration Security Device Support Enable Disable the TPM support feature Options available Enable Disable Default setting is Disable Current Status Information Displays current T...

Страница 81: ...81 BIOS Setup 5 2 13 NVMe Configuration NVMe controller and Drive information Displays the NVMe devices connected to the system...

Страница 82: ...82 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related subm...

Страница 83: ...the Core Performance Boost Options available Disabled Auto Default setting is Auto Global C state Control Controls the IO based C state generation and DF C states Options available Disabled Enabled Au...

Страница 84: ...BIOS Setup 84 5 3 1 1 Core Thread Enablement...

Страница 85: ...settings Agree Agrees with the Core Thread Enablement settings Downcore control Sets the number of cores to be used Once this option has been used to remove any cores a POWER CYCLE is required in orde...

Страница 86: ...ions and it will be ignored if the memory doesn t support the selected option Options available None Channel Die Socket Auto Default setting is Auto Memory interleaving size Controls the memory interl...

Страница 87: ...87 BIOS Setup 5 3 3 UMC Common Options UMC Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items...

Страница 88: ...etup 88 5 3 3 1 DDR4 Common Options DDR4 Common Options Enforce POR Press Enter to configure the enforce POR Common RAS Press Enter to configure the common RAS Security Press Enter to configure the se...

Страница 89: ...89 BIOS Setup 5 3 3 1 1 Enforce POR...

Страница 90: ...CAUSED BY USE OF YOUR AMD PROCESSOR OUTSIDE OF SPECIFICATION OR IN EXCESS OF FACTORY SETTINGS ARE NOT COVERED UNDER YOUR AMD PRODUCT WARRANTY AND MAY NOT BE COVERED BY YOUR SYSTEM MANUFACTURER S WARRA...

Страница 91: ...ol Size Configures the DRAM ECC Symbol Size x4 x8 EMC_CH EccCtrl ECCsymbolSize Options available x4 x8 Auto Default setting is Auto DRAM ECC Enable Enable disable DRAM ECC When set to Auto it will set...

Страница 92: ...ity TSME Transparent SME AddrTweakEn 1 ForceEncrEn 1 DataEncrEn 0 Options available Enabled Disabled Auto Default setting is Auto Data Scramble Data scrambling DataScrambleEn Options available Enabled...

Страница 93: ...available Disabled Auto Default setting is Auto BankGroupSwap Configures the BankGroupSwap BankGroupSwap BGS is a new memory mapping option in AGESA that alters how applications get assigned to physic...

Страница 94: ...configure the NB configuration Determinism Slider Auto Use default performance determinism settings Options available Auto Power Performance Default setting is Auto cTDP Control Auto Use the fused cTD...

Страница 95: ...95 BIOS Setup 5 3 5 FCH Common Options FCH Common Options AC Power Loss Options Press Enter to configure the AC loss control...

Страница 96: ...OS Setup 96 5 3 5 1 AC Power Loss Options AC Power Loss Options AC Loss Control Selects the AC Loss Control method Options available Always Off Always On Reserved Previous Default setting is Always Of...

Страница 97: ...e thread Auto 2T two thread if capable Options available Off Auto Default setting is Auto PCIe Link Training Type Debugges the PCIe link training issue in 1 or 2 steps Options available 1 Step 2 Step...

Страница 98: ...North Bridge Configuration Memory Information Total Memory Displays the total memory information Memory Configuration Press Enter to configure the north bridge memory CPU 0 Information Press Enter to...

Страница 99: ...Memory Configuration Memory Configuration Memory Clock This option allows user to select different memory clock Default value is 800 Mhz Options available Auto 1333MHz 1600MHz 1866MHz 2133MHz 2400MHz...

Страница 100: ...BIOS Setup 100 5 4 1 2 CPU 0 Information CPU 0 Information Displays the Information related to CPU 0...

Страница 101: ...dress Command Parity With Replay RCD Parity Enable disable Registering Clock Driver RCD Parity RDimmParEn Options available Enabled Disabled Default setting is Enabled DRAM Address Command Parity Retr...

Страница 102: ...ng Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Note Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is...

Страница 103: ...r configuration of advanced items View FRU Information Press Enter to view the advanced items BMC network configuration Press Enter for configuration of advanced items IPv6 BMC Network Configuration P...

Страница 104: ...ailable No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do N...

Страница 105: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Страница 106: ...statically or dynamically by BIOS or BMC Do nothing option will not modify any BMC network parameters during BIOS phase If you select Mode1 Mode2 or Mode3 option it will request you complete the netw...

Страница 107: ...amicBmcDhcp Default setting is Unspecified Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for...

Страница 108: ...Pv6 BMC Lan Option Note Enable Disable IPv6 BMC LAN channel function When this item is disabled the system will not modify any BMC network during BIOS phase Options available Enable Disable Default se...

Страница 109: ...mic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP Please note that this item is configurable when IPv6 BMC Lan Option is set to Enable IPv6 BMC Lan IP Address Pr...

Страница 110: ...ange all settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set...

Страница 111: ...etup mode Secure Boot Displays the Secure Boot function is actived or not actived Vendor Keys Displays the Vendor Keys function is actived or not actived Attempt Secure Boot Secure Boot activated when...

Страница 112: ...ws all the files being loaded before Windows loads and gets to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases...

Страница 113: ...Press Enter to save all Secure Boot Keys and Key variables Secure Boot variable Displays the current status of the variables used for secure boot Platform Key PK Displays the current status of the Pla...

Страница 114: ...TimeStamps DBT Displays the current status of the Authorized TimeStamps Database Press Enter to configure a new DBT or load additional DBT from storage devices Options available Set New Append OsReco...

Страница 115: ...meric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Full Screen LOGO Show Enable Disable the Full Scre...

Страница 116: ...By default the server searches for boot devices in the following secquence 1 Hard disk drive 2 CD COM DVD drive 3 USB device 4 Network device 5 UEFI device UEFI Network Drive BBS Priorities Press Ente...

Страница 117: ...rities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error messag...

Страница 118: ...rities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message i...

Страница 119: ...OS setup Options available Yes No Save Changes Saves changes made in the BIOS setup Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters S...

Страница 120: ...e 0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public inter...

Страница 121: ...BL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Inte...

Страница 122: ...init 0xE057 Exit point CPU APOB EDC info init 0xE058 5 9 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 5 9 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3 0x...

Страница 123: ...de 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug co...

Страница 124: ...Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGM...

Страница 125: ...AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allo...

Страница 126: ...nitialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchron...

Страница 127: ...DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for He...

Страница 128: ...Error 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted...

Страница 129: ...30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Er...

Страница 130: ...107 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTrai...

Страница 131: ...Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Cha...

Страница 132: ...A187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For...

Страница 133: ...code calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate...

Страница 134: ...V2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save ar...

Страница 135: ...and MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mai...

Страница 136: ...0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910...

Страница 137: ...NbioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0...

Страница 138: ...ate exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 5 10 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX...

Страница 139: ...h finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 F...

Страница 140: ...xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH Ini...

Страница 141: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 11 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the A...

Отзывы: