- 85 -
BIOS Setup
Parameter
Description
PCH SATA Configuration
(continued)
Port 0/1/2/3/4/5/6/7
– Enable/Disable Port 0/1/2/3/4/5/6/7 device.
– Options available: Enable, Disable. Default setting is
Enable
.
Hot Plug (for Port 0/1/2/3/4/5/6/7)
(Note 2)
– Enable/Disable HDD Hot-Plug function.
– Options available: Enable, Disable. Default setting is
Enable
.
Spin Up Device (for Port 0/1/2/3/4/5/6/7)
(Note 2)
– On an edge detect from 0 to 1, the PCH starts a COM reset
initialization to the device.
– Options available: Enable, Disable. Default setting is
Disable
.
PCH sSATA Configuration
sSATA Controller
– Enable/Disable sSATA controller.
– Options available: Enable, Disable. Default setting is
Enable
.
Configure sSATA as
–
Configures on chip SATA type.
– AHCI Mode: When set to AHCI, the SATA controller enables its AHCI
functionality. Then the RAID function is disabled and cannot be access
the RAID setup utility at boot time.
– RAID Mode: When set to RAID, the SATA controller enables both its
RAID and AHCI functions. You will be allowed to access the RAID
setup utility at boot time.
– Options available: AHCI, RAID. Default setting is
AHCI
.
Alternate Device ID on RAID
(Note 1)
– Enable/Disable Alternate Device ID on RAID mode.
– Options available: Enable, Disable. Default setting is
Disabled
.
sSATA Port 0/1/2/3/4/5
–
The category identifies sSATA hard drives that are installed in the
computer. System will automatically detect HDD type.
Port 0/1/2/3/4/5
– Enable/Disable Port 0/1/2/3/4/5 device.
– Options available: Enable, Disable. Default setting is
Enable
.
Hot Plug (for Port 0/1/2/3/4/5)
(Note 2)
– Enable/Disable HDD Hot-Plug function.
– Options available: Enable, Disable. Default setting is
Disable
.
Spin Up Device (for Port 0/1/2/3/4/5)
(Note 2)
– On an edge detect from 0 to 1, the PCH starts a COM reset
initialization to the device.
– Options available: Enable, Disable. Default setting is
Disabled
.
(Note 1) Only appears when HDD sets to
RAID
Mode.
(Note 2) Only Supported when HDD is in
AHCI
or
RAID
Mode.
Содержание R182-NA1
Страница 1: ...R182 NA1 3rd Gen Intel Xeon Scalable DP Server System 1U 10 Bay Gen4 NVMe User Manual Rev 1 0 ...
Страница 9: ... 9 5 8 1 PEI Beep Codes 107 5 8 2 DXE Beep Codes 107 ...
Страница 10: ... 10 This page intentionally left blank ...
Страница 16: ...Hardware Installation 16 1 3 System Block Diagram ...
Страница 42: ...System Hardware Installation 42 This page intentionally left blank ...
Страница 67: ... 67 BIOS Setup 5 2 12 Intel R i350 Gigabit Network Connection ...
Страница 72: ... 72 BIOS Setup 5 3 1 Processor Configuration ...