- 31 -
System Hardware Installation
3-6 Removing and Installing the Heat Sink
Read the following guidelines before you begin to install the heat Sink:
•
Always turn off the computer and unplug the power cord from the power outlet before installing
the heat sink to prevent hardware damage.
•
Unplug all cables from the power outlets.
•
Disconnect all telecommunication cables from their ports.
• Place the system unit on a flat and stable surface.
•
Open the system according to the instructions.
WARNING!
Failure to turn off the server before you start installing components may cause serious damage. Do
not attempt the procedures described in the following sections unless you are a qualified service
technician.
Follow these instructions to install the heatsink:
1. Loosen the four captive screws securing the heat sink in place in reverse the order (4
g
3
g
2
g
1).
2. Lift and remove the heatsink from the system.
3. To install the heatsink, reverse steps 1-2 while ensuring that you tighten the captive screws in
sequential order (1
g
2
g
3
g
4) as seen in the image below.
1
3
2
4
1
2
Содержание G492-Z51
Страница 1: ...G492 Z51 HPC Server 4U DP 10 x Gen4 GPU Server User Manual Rev 1 0 ...
Страница 10: ... 10 This page left intentionally blank ...
Страница 16: ...Hardware Installation 16 This page intentionally left blank ...
Страница 28: ...System Hardware Installation 28 3 5 4 6 6 6 ...
Страница 30: ...System Hardware Installation 30 3 5 4 ...
Страница 42: ...System Hardware Installation 42 4 ...
Страница 46: ...System Hardware Installation 46 This page left intentionally blank ...
Страница 65: ... 65 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Страница 70: ...BIOS Setup 70 5 2 11 SATA Configuration ...
Страница 75: ... 75 BIOS Setup 5 2 16 Intel R Ethernet Controller X550 ...