BIOS Setup
- 92 -
Parameter
Description
NBIO RAS Common Options
(continued)
System Hub Watchdog Timer
–
Enter a value. This value specifies the timer interval of the
SYSHUB watchdog timer in miliseconds.
SLINK Read Response OK
–
This value specifies whether SLINK read response errors are
converted to an Okay response. When this value is set to TRUE,
read response errors are converted to Okay responses with data
of all FFs. When set to FALSE read response errors are not
converted.
– Options available: Enabled/Disabled. Default option is Disabled.
SLINK Read Response Error Handling
–
This value specifies whether SLINK write response errors are
converted to an Okay response. When this value is set to 0, write
response errors will be logged in the MCA. When set to 1, write
response errors will trigger an MCOMMIT error. When this value is
set to 2, write response errors are converted to Okay responses.
– Options available: Enabled/Trigger MCOMMIT Error/Log Errors in
MCA. Default option is Log Errors in
MCA
.
Log Poison Data from SLINK
–
This value specifies whether poison data propogated from SLINK
will generate a deferred error. When this value is set to TRUE,
deferred errors are enabled. When set to FALSE, errors are not
generated.
– Options available: Enabled/Disabled. Default option is
Disabled
.
PCIe Aer Reporting Mechanism
– This value selects the method of reporting AER errors from PCI
Express. A value of 0 indicates that the hardware will report the
error through MCA. A value of 1 allows OS First handling of the
errors through generation of a system control interrupt (SCI). A
value of 2 provides for Firmware First handling of errors through
generation of a system management interrupt (SMI).
– Options available: OS First/MCA/Auto. Default option is
Auto
.
Edpc Control
– (0) Disabled; (1) Enabled; (3) Auto.
– Options available: Disabled/Enabled/Auto. Default option is
Disabled
.
NBIO Poison Consumption
– Options available: Auto/Enabled/Disabled. Default option is
Auto
.
Содержание G492-Z51
Страница 1: ...G492 Z51 HPC Server 4U DP 10 x Gen4 GPU Server User Manual Rev 1 0 ...
Страница 10: ... 10 This page left intentionally blank ...
Страница 16: ...Hardware Installation 16 This page intentionally left blank ...
Страница 28: ...System Hardware Installation 28 3 5 4 6 6 6 ...
Страница 30: ...System Hardware Installation 30 3 5 4 ...
Страница 42: ...System Hardware Installation 42 4 ...
Страница 46: ...System Hardware Installation 46 This page left intentionally blank ...
Страница 65: ... 65 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Страница 70: ...BIOS Setup 70 5 2 11 SATA Configuration ...
Страница 75: ... 75 BIOS Setup 5 2 16 Intel R Ethernet Controller X550 ...