GIGA I2FZP Скачать руководство пользователя страница 6

4 - INSTALLATION INSTRUCTIONS

502_03

- GAS KITCHENS

6

· 16

4.1 Safety rules

• Installation, modifications and maintenance of the appliance

must be carried out by authorised personnel in compliance with
current safety standards. The manufacturer declines all responsi-
bility for failure to comply with these obligations.

•  In compliance with international regulations, when connecting

the appliance to the mains power supply, a device with a mini-
mum aperture of 3 mm between contacts must be fitted
upstream of the appliance, allowing omnipolar disconnection of
the appliance from the mains. Also, a high-sensitivity automatic
differential switch must be installed which protects against direct
or indirect contact with live electrical parts and against current
leakage (maximum current leakage permissible by regulations is
1 mA/kW).

•  Compare technical datas on grey stickers to those written on this

manual and present power supply.

•  Do not bend, crush or damage the cables against sharp corners.

•  Lay the cables so as to avoid contact with extremely hot surfaces.

• Connection to the grid must be carried out with at least a cable

type NYM or H07RN-F.

•  The cable - which is totally sheathed – must be led inside the

appliance through the cable clamp and cable raceway installed
on the appliance.

•  Ventilation system installation can be carried out only by expert

personnel.

•  If the appliance is to be installed near walls, dividing walls, kit-

chen equipment or decorative panelling, these should be in non-
inflammable material. If not, all appliances must be coated with
thermal-insulation fireproof material. Make sure that all fire pre-
vention standards and safety precautions are strictly adhered to.

4.2 Structure, equipment and safety devices
of the unit 

18/10 chrome-nickel steel outer panelling. 

4.2.1 Cooking zone 

•  Burner with stabilized flame.

•  Pilot flame.

•  Gas cocks with safety and adjustable from maximum to minimum.

•  Thermoelectric ignition safety.

• Enamelled cast-iron pan supports.

•  The bodies of the burners, the injector-holder cups and the flame

spreaders are made of nickelled cast-iron.

•  18/10 chrome-nickel steel cooking top.

•  Knobs in thermosetting material.

4.3 Assembly

4.3.1 Installation premises

The appliance should be installed in a well-ventilated room, and if
possible under a range hood (check current regulations).

The appliance can be installed on its own or with other similar
equipment.

If the appliance is to be installed near inflammable walls, a minimum
distance of 150 mm around the sides and back should be allowed. 

If this distance cannot be obtained, take proper heat-protection
action such as fitting tiles or thermal radiation protection material
to the walls.  

Before connecting the appliance to the gas supply, check on the
data plate that the appliance is suitable and type-tested for the
type of gas available. 

If the type of gas indicated on the data plate of the appliance does
not correspond to the gas which is present, refer to the paragraph
"Conversion and adaptation". 

4.3.2 Statutory regulations and technical requirements

During installation of the appliance, the following regulations must
be adhered to:

•  Relevant legal directives;

•  Local building and combustion regulations;

•  "Technical rules for gas systems" worksheet;

•  "Technical rules for liquid gas" worksheet;

•  “Gas installations in industrial kitchens” worksheet;

•  Relative accident prevention standards;

•  Local gas utility regulations.

•  Local building and fire codes.

4.3.3 Installation

Before installation, gas connection, power check, conversion or
adjustment and start up ask for gas supply company advice.

4.3.4 Gas connection

The R 1/2” gas connection of the appliance to the gas pipeline can
either be permanently fixed to the mains or made detachable using
an approved cock.    

After completing gas connection, check for leaks using a special
leak-detector spray.

4.3.5 Smoke extraction

These kitchens are type A appliances, thus no smoke extraction sys-
tem is required.

For the ventilation of the room where the appliance is installed,
refer to related legislation.

4.3.6 Equipotential

The appliance must be hooked up to a unipotential system.  The
required terminal is located near the cord inlet. It is marked by a
tag with a symbol

.

The manufacturers cannot be held responsible for any dama-
ge due to inadequate or incorrect installation or non-com-
pliance with the regulations.

Содержание I2FZP

Страница 1: ...502_03 Instructions for installation use and maintenance 09 2015 COPYRIGHT 2004 GIGA GRANDI CUCINE SRL GAS KITCHENS I2FZP I4FZP I6FZP ...

Страница 2: ...CHARACTERISTICS 502_03 GAS KITCHENS 2 16 Supplied by Date Customer Service FAX e mail ...

Страница 3: ...me 11 5 1 7 Checking the primary air 11 5 1 8 Operation Control 12 5 1 9 Operator training 12 5 1 10 Conversion and adjustment 12 5 1 11 Replacement of burner nozzles 12 5 1 12 Setting reduced capacity power 12 5 1 13 Replacement of pilot nozzle open flames 12 5 2 Maintenance 12 5 3 Replacing parts 12 5 3 1 Gas valve open flames 12 5 3 2 Thermocouple open flames 12 6 Instructions for use 13 6 1 Sa...

Страница 4: ... 14 5 90 90 407 407 33 33 170 170 219 5 219 5 204 5 204 5 15 15 100 100 14 5 14 5 90 90 15 15 755 755 716 716 777 777 11 5 11 5 800 800 48 48 135 135 67 67 67 67 1116 1116 755 755 67 67 15 15 90 90 14 5 14 5 100 100 1200 1200 1177 1177 11 5 11 5 257 257 48 48 257 257 48 48 257 257 48 48 257 257 7 8 kW 4 0 kW 4 0 kW 4 0 kW 7 8 kW 4 0 kW 4 0 kW 7 8 kW 4 0 kW 7 8 kW 7 8 kW 4 0 kW B B B B B B B B B B ...

Страница 5: ...611 200 Adjustable 135 75 27 19 1 29 2 58 3 47 0 95 1 91 2 57 Hour consumption G20 m3 h G25 m3 h G30 G31 kg h I2FZP I4FZP I6FZP Model Gas connection values Methane gas 2H Liquid gas 3 Model I2FZP I4FZP I6FZP Description 2 burners with pilot flame 4 burners with pilot flame 6 burners with pilot flame Dimensions in mm LxPxH 400 x 610 x 220 800 x 610 x 220 1200 x 610 x 220 N 51BQ2896 51BQ2896 51BQ289...

Страница 6: ...t iron 18 10 chrome nickel steel cooking top Knobs in thermosetting material 4 3 Assembly 4 3 1 Installation premises The appliance should be installed in a well ventilated room and if possible under a range hood check current regulations The appliance can be installed on its own or with other similar equipment If the appliance is to be installed near inflammable walls a minimum distance of 150 mm...

Страница 7: ... worktable and appliance are clamped with six M5 screws first drill the relevant holes in the worktable as described in fig 2 In order to prevent liquids from leaking in between the lining and the appliance it is necessary to waterproof the leaks with sanitary silico ne anti mould and heat resistant to at least 100 C i e Pactan 6076 The knob position is fixed therefore in the design of the parts w...

Страница 8: ... 15 100 100 90 90 33 33 60 60 360 360 MIN 50 MIN 50 585 585 Ø Ø 7 7 Ø Ø 7 7 33 33 1177 1177 1160 1160 257 257 257 257 38 38 Ø Ø 7 7 33 33 257 257 257 257 38 38 33 33 257 257 257 257 38 38 Hole for fixing screw Hole for fixing screw Ventialtion openings Ventialtion openings Appliance back wall Appliance back wall 585 585 585 585 Fig 2 ...

Страница 9: ... 257 257 585 585 27 MIN 27 MIN 93 93 15 15 42 42 55 55 257 257 360 360 406 406 MIN 50 MIN 50 585 585 616 616 Ø Ø 7 7 Silicone Silicone 3 3 Ø Ø 7 7 Ø Ø 7 7 1177 1177 1206 1206 1160 1160 257 257 257 257 257 257 257 257 33 33 38 38 257 257 257 257 Ventialtion openings Ventialtion openings Appliance back wall Appliance back wall 585 585 616 616 585 585 616 616 33 33 38 38 33 33 38 38 Fig 3 ...

Страница 10: ...altion openings Ventialtion openings 43 43 30 MIN 30 MIN 100 100 90 90 10 MAX 10 MAX 255 MIN 255 MIN 20 20 604 604 outside outside 604 604 outside outside 604 604 outside outside Fig 4 1 Fig 4 1 794 794 outside outside MIN 50 MIN 50 Appliance back wall Appliance back wall 1194 1194 outside outside Support Support Fig 4 ...

Страница 11: ...ominal pressure are obtained by consulting the table for the adjustment of the gas passage table 1 WARNING There is no pre adjustment device for the nominal power 5 1 5 Power check for operation with liquid gas Check if the type of nozzles used meet manufacturer requirements Check that the pressure reducer installed in the system has an outlet pressure which is compliant with paragraph 5 1 2 Check...

Страница 12: ... way down for operation with methane use the gas flow table to check the value in l min with respect to the operating alorific value meas urement in accordance with the volumetric method Start the appliance in accordance with the instructions Turn the knob to the minimum position and use screw 5 to adjust the flow clock wise flow reduction conter clockwise flow increase 5 1 13 Replacement of pilot...

Страница 13: ... repeat the operation Then place the knob in the maximum or minimum position so that the main burner ignites To shut off the burner turn the knob to the right to the spark posi tion and the main burner will go out To shut off the pilot light place the knob in position 0 Shutdown To shut off the main burner turn the knob to the spark position Only the pilot flame will remain lit For complete shutdo...

Страница 14: ...less steel equipment surfaces must be kept clean and in con tact with air at all times When not running keep appliance doors open so as to allow air to run through it Regularly remove calcium grease starch and egg white deposits where rust may build up if there is lack of air Do not use bleach ing products or products containing chloride Follow all indica tions given by the company concerning spec...

Страница 15: ...collection centre or returned to the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste Suitable separated collection so that the unit no longer used can be sent ...

Страница 16: ...idicucine it WARNING THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED ...

Отзывы: