2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

502_03

- GAS KITCHENS

5

· 16

These appliances are used for professional purposes. Installation,
repair and use must be carried out by expert personnel.

These instructions for installation are for our gas kitchens set up for
the category in the table on page 5. The data plate is located on the
front part of the appliance (on the control panel).

Primary air distance “A”

Methane gas G20

Liquid gas G30/G31

TABLE 1

Category

Construction type

Air necessary for combustion

Nominal thermal power

Minimum thermal power

Overall thermal power (gas)

Connection pressure

Methane gas 2H

Liquid gas 3+

Nozzles Ø 1/100 mm

Main burner 

G20

G30/G31

(HuB = 9.45 kWh/m

3

) in m

3

/h

(HuB = 12.87 kWh/kg) in kg/h

Nominal thermal power

Minimal thermal capacity

Nominal thermal power

Minimal thermal capacity

G20

G30/31

20 mbar

28/37 mbar

12.2

24.4

32.8

kW

kW

kW

II2H3+

A

m

3

/h

kW

kW

No. of nozzles, pilot burner

G20

G30/G31

7

Open

X

 

Ø 100

8

4.0

1.2

0.423

0.313

145

Adjustable

100

45

27

19

15

Open

Z

 

Ø 120

14

7.8

2.9

0.825

0.611

200

Adjustable

135

75

27

19

1,29

2,58

3,47

-

-

-

-

0,95

1,91

2,57

Hour consumption

G20

m

3

/h

G25

m

3

/h

G30/G31

kg/h

I2FZP

I4FZP 

 

I6FZP 

Model

Gas connection values

Methane gas 2H

Liquid gas 3+

Model

I2FZP

I4FZP

I6FZP

Description

2 burners with pilot flame

4 burners with pilot flame

6 burners with pilot flame

Dimensions in mm.

(LxPxH)

400 x 610 x 220

800 x 610 x 220

1200 x 610 x 220

N.

51BQ2896

51BQ2896

51BQ2896

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

G30/G31

28/37 mbar

G20

20 mbar

Содержание I2FZP

Страница 1: ...502_03 Instructions for installation use and maintenance 09 2015 COPYRIGHT 2004 GIGA GRANDI CUCINE SRL GAS KITCHENS I2FZP I4FZP I6FZP ...

Страница 2: ...CHARACTERISTICS 502_03 GAS KITCHENS 2 16 Supplied by Date Customer Service FAX e mail ...

Страница 3: ...me 11 5 1 7 Checking the primary air 11 5 1 8 Operation Control 12 5 1 9 Operator training 12 5 1 10 Conversion and adjustment 12 5 1 11 Replacement of burner nozzles 12 5 1 12 Setting reduced capacity power 12 5 1 13 Replacement of pilot nozzle open flames 12 5 2 Maintenance 12 5 3 Replacing parts 12 5 3 1 Gas valve open flames 12 5 3 2 Thermocouple open flames 12 6 Instructions for use 13 6 1 Sa...

Страница 4: ... 14 5 90 90 407 407 33 33 170 170 219 5 219 5 204 5 204 5 15 15 100 100 14 5 14 5 90 90 15 15 755 755 716 716 777 777 11 5 11 5 800 800 48 48 135 135 67 67 67 67 1116 1116 755 755 67 67 15 15 90 90 14 5 14 5 100 100 1200 1200 1177 1177 11 5 11 5 257 257 48 48 257 257 48 48 257 257 48 48 257 257 7 8 kW 4 0 kW 4 0 kW 4 0 kW 7 8 kW 4 0 kW 4 0 kW 7 8 kW 4 0 kW 7 8 kW 7 8 kW 4 0 kW B B B B B B B B B B ...

Страница 5: ...611 200 Adjustable 135 75 27 19 1 29 2 58 3 47 0 95 1 91 2 57 Hour consumption G20 m3 h G25 m3 h G30 G31 kg h I2FZP I4FZP I6FZP Model Gas connection values Methane gas 2H Liquid gas 3 Model I2FZP I4FZP I6FZP Description 2 burners with pilot flame 4 burners with pilot flame 6 burners with pilot flame Dimensions in mm LxPxH 400 x 610 x 220 800 x 610 x 220 1200 x 610 x 220 N 51BQ2896 51BQ2896 51BQ289...

Страница 6: ...t iron 18 10 chrome nickel steel cooking top Knobs in thermosetting material 4 3 Assembly 4 3 1 Installation premises The appliance should be installed in a well ventilated room and if possible under a range hood check current regulations The appliance can be installed on its own or with other similar equipment If the appliance is to be installed near inflammable walls a minimum distance of 150 mm...

Страница 7: ... worktable and appliance are clamped with six M5 screws first drill the relevant holes in the worktable as described in fig 2 In order to prevent liquids from leaking in between the lining and the appliance it is necessary to waterproof the leaks with sanitary silico ne anti mould and heat resistant to at least 100 C i e Pactan 6076 The knob position is fixed therefore in the design of the parts w...

Страница 8: ... 15 100 100 90 90 33 33 60 60 360 360 MIN 50 MIN 50 585 585 Ø Ø 7 7 Ø Ø 7 7 33 33 1177 1177 1160 1160 257 257 257 257 38 38 Ø Ø 7 7 33 33 257 257 257 257 38 38 33 33 257 257 257 257 38 38 Hole for fixing screw Hole for fixing screw Ventialtion openings Ventialtion openings Appliance back wall Appliance back wall 585 585 585 585 Fig 2 ...

Страница 9: ... 257 257 585 585 27 MIN 27 MIN 93 93 15 15 42 42 55 55 257 257 360 360 406 406 MIN 50 MIN 50 585 585 616 616 Ø Ø 7 7 Silicone Silicone 3 3 Ø Ø 7 7 Ø Ø 7 7 1177 1177 1206 1206 1160 1160 257 257 257 257 257 257 257 257 33 33 38 38 257 257 257 257 Ventialtion openings Ventialtion openings Appliance back wall Appliance back wall 585 585 616 616 585 585 616 616 33 33 38 38 33 33 38 38 Fig 3 ...

Страница 10: ...altion openings Ventialtion openings 43 43 30 MIN 30 MIN 100 100 90 90 10 MAX 10 MAX 255 MIN 255 MIN 20 20 604 604 outside outside 604 604 outside outside 604 604 outside outside Fig 4 1 Fig 4 1 794 794 outside outside MIN 50 MIN 50 Appliance back wall Appliance back wall 1194 1194 outside outside Support Support Fig 4 ...

Страница 11: ...ominal pressure are obtained by consulting the table for the adjustment of the gas passage table 1 WARNING There is no pre adjustment device for the nominal power 5 1 5 Power check for operation with liquid gas Check if the type of nozzles used meet manufacturer requirements Check that the pressure reducer installed in the system has an outlet pressure which is compliant with paragraph 5 1 2 Check...

Страница 12: ... way down for operation with methane use the gas flow table to check the value in l min with respect to the operating alorific value meas urement in accordance with the volumetric method Start the appliance in accordance with the instructions Turn the knob to the minimum position and use screw 5 to adjust the flow clock wise flow reduction conter clockwise flow increase 5 1 13 Replacement of pilot...

Страница 13: ... repeat the operation Then place the knob in the maximum or minimum position so that the main burner ignites To shut off the burner turn the knob to the right to the spark posi tion and the main burner will go out To shut off the pilot light place the knob in position 0 Shutdown To shut off the main burner turn the knob to the spark position Only the pilot flame will remain lit For complete shutdo...

Страница 14: ...less steel equipment surfaces must be kept clean and in con tact with air at all times When not running keep appliance doors open so as to allow air to run through it Regularly remove calcium grease starch and egg white deposits where rust may build up if there is lack of air Do not use bleach ing products or products containing chloride Follow all indica tions given by the company concerning spec...

Страница 15: ...collection centre or returned to the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste Suitable separated collection so that the unit no longer used can be sent ...

Страница 16: ...idicucine it WARNING THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS BOOKLET DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED ...

Отзывы: