PROFESSIONAL AUTOMATIC SYSTEM FOR GATES AND GARAGE DOORS
FAULT
POSSIBLE CAUSE / REMEDY
Power LED of f
Check the fuses and the power cable (1 A)
The card does not learn the TX code
Check the maximum number of storable codes
Check the frequency of the radio control and the receiver
Fast flashing of the programming LED (PROG.)
Max. number of codes reached
Memor y fault
The operator does not open
Check the opening limit switch
Check the connection between card and limit switch
-
-
-
Cour tesy lamp not working
Check the lamp and the fuse F3
If the operator is batter y-powered
(230VAC power supply failure)
the cour tesy lamp is disabled.
-
-
The operator opens but does not reclose
Check the inputs of the safety switches, photocells, Stop, etc.
Check the Star t input, it must be open
Check connection and opening limit switch
-
-
-
-
-
-
-
The operator does not decelerate
Check door balancing
Check limit switch inter vention
-
-
TROUBLESHOOTING
Before any installation or maintenance operation, ensure that the power supply has been disconnected.
Use only original Gi.Bi.Di. spare parts and accessories.
Photocell entrance does not inter vene
Verify that DIP 5 is in OFF
-