4
5
1.4 - CAP R868/916 RECEIVER
1.5 - CAP MAGIN
green
green
= INH
black = GND
red
= 9 Vdc
red
= NO-TOUCH activated
= NO-TOUCH inhibited
GREY - BLACK magnets
position depends on the
direction of the gate.
CAP MAGIN LED must be GREEN
while gate is closing.
RED when gate is stopped.
MAGNETS
CAP MAGIN
DETECTOR
2m
GREY
BLACK
2 - DETECTION PRINCIPLES
CAP T detects objects near the safety edge of the gate by detecting variations between conductive part of the gate
and conductive parts of the safety edge.
For this reason CAP T has a cable to connect GND to the metal part of the gate.
It is very important for the correct function of the NO TOUCH detection that the ground reference tab is properly
connected to the gate.
The amount of detection/sensitivity is going to depend on:
• Size of the conductive part of the object.
• Distance from the object to the edge of the gate.
Maximum safety edge length = 2.5 m.
CAPTIVE
CAPTIVE
EN
EN
CHECK BUTTON
Verifies the proper
function of the system
LEDS
PROGRAMMING BUTTON
Memorise new transmitters
MR BRIDGE
Transmitters memory reset
ATEST INPUT
12/24V ac/dc 5mA input for testing system
and/or
activation of safety edge (SW2)
(SW4)
INHIBITION INPUT
NO-TOUCH inhibition activation (SW3)
OPTIONS SELECTOR
12/24 VAC/DC
Input power supply
(9-35 Vdc, 8-28 Vac)
R1/R2 OUTPUTS
Relay outputs to inform
the control panel of the
safety edge status,
normally closed contact (CS)
and 8k2 (BS) for each relay
LED
R1
CHECK
R2
OFF
Normal
use
Safety edge in relay 1 activated or
not connected
Safety edge in relay 2 activated or
not connected
See signal coverage table
ON
SW
FUNCTION
ON
7s
30s
ON
WORK
OFF
SW3
Inhibition
Open contact
Close contact
Functioning
mode
ATEST
polarity
Autocheck
period
SW1
SW2
SW4
12/24V
0V
12/24V
0V