To avoid false detections and ensure a
longer NO TOUCH range, the gap between
the “internal wires” and the gate must be
as big as possible.
GROUND cable must be
connected to the metallic part
of the gate.
Safety edge wire
must be as short
as possible to
avoid vibrations.
MAGNET
IN
H
IB
IT
IO
N
Z
O
N
E
IMPORTANT
CAP
MAGIN
CAP ACTIVE
OR CAP T
CAP R868
MAGNET
CLOSING GATE
Do not place
metal surfaces
between transmitter
and receiver.
6
7
3 - INSTALLATION
3.1 - CAP T/CAP R
3.2 - CAP ACTIVE
RECEIVER
TRANSMITTER
AVOIDING EXCESSIVE VIBRATION IS A MUST.
Use safety edges where
conductor cannot be moved easily
by the movement of the gate.
Use
metallic profiles appropriated for the safety edge
used.
Non disporre le
superfici di metallo
tra il trasmettitore
e il ricevitore.
Fix the clip to the
column or to the gate
as set out in
(h/4 h/2 / h-h/4)
Fix the edge to the
CLIP in the column
or to the gate, and
secure with screws,
see (k/j).
CAP ACTIVE safety
edge must be
positioned vertically,
taking care to mount
the card with the board
in the upper part.
Ground cable must be
fixed to the gate.
Make sure that ground and
antenna wires are NOT in
contact.
Remove the
locking pin (1c)
NOTE: in order to improve
the discharge of any sediment
that may be found inside
the bottom cap, it is advisable
to drill a hole, as shown in (1d)
Ø 5mm
3.2.1
CABLE TENSIONING AND CALIBRATION
Optimum operation
of the device is
achieved, with
the electrical
intervention,
with a deformation
at the centre of the
safety edge equal
to about 20 mm.
The safety edge is
already provided with
pretensioned cable.
However, you can make
further adjustment by
turning the SCREW on
the arm of the upper
support of the edge.
- Turning clockwise will
increase the sensitivity
of the edge (+)
- Turning counterclockwise
will decrease the sensitivity
of the edge (-)
CAPTIVE
CAPTIVE
EN