SC230
Description
DIP 1
DIP 2
DIP
OFF
OFF
Status
Function
STEP–BY-STEP
WITH STOP
8 - DIP SWITCH SW1
The settings are stored during the rest phase (gate closed).
OFF
ON
CONDOMINIUM
ON
OFF
STEP–BY-STEP
DIP 3
If Start button is held down:
OPENS
If Pedestrian button is held down:
CLOSES
The SAFETY 8K2, PHOTO inputs and the decelerations will not be active.
STOP 8K2 will be enabled.
Not manageable with radio control.
Enables the pre-flashing of 3 seconds before the activation of the motor in opening and
closing.
Disables the pre-flashing.
ON
ON
ON
OFF
DEAD MAN
PRE-FLASHING
Operation in reply to a START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
STOPS
→
Ÿ
Gate open
CLOSES
→
Ÿ
During closing
STOPS
→
Ÿ
After a STOP
inverts the motion
→
Operation in reply to a START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
CLOSES
→
Ÿ
Gate open
CLOSES
→
Ÿ
During closing
OPENS
→
Operation in reply to a START command:
Ÿ
Gate closed
OPENS
→
Ÿ
During opening
IRRELEVANT
→
Ÿ
Gate open
Recharges the automatic closing time if the automatic
→
reclosing is enabled, otherwise closes.
Ÿ
During closing
OPENS
→
The DEFAULT settings are coloured in grey
6 - ELECTRICAL CONNECTIONS: FASTON
Faston
CN2 CN3
CN4 CN5
Description
Ground connection
Motor capacitor connection
Protects the ACCESSORIES and SAFETY DEVICES power supply outputs
500 mA
FAST
Protects the control unit at 115 Vac power supply input
5 A
500 mA
FAST
FAST
F1
F2
F3
Description
Position
Value
Type
7 - PROTECTION FUSES
Protects the electronic card
UK
13
Содержание AS05710/115V
Страница 26: ...SC230 NOTAS 26 ...