11. Adding New Cards by Master Card 

     

   

a.  

           

 1. 

Read master card once (1 beep, Right Yellow LED stay on) 

             

2.

 Enter slot position 001~999 (Left Green LED stay on, Right Yellow 

LED rapid flash to indicate the slot position is available 

           

 3.

 Read new card (1 beep), then enter 5-digit PIN 99999 (1 beep, Right 

Yellow LED stay on) 

             

4. 

Press # (1 beep , Right Green LED stay on) back to standby mode   

       

 b.  

             

1.

 Read master card once (1 beep, Right Yellow LED stay on) 

             

2.

 Enter slot position 001~999 (Left Red LED stay on, Right Yellow LED 

rapid flash to indicate the slot position is unavailable) 

             

3.

 Press

**

(1 beep, Left Green LED stay on, Right Yellow LED rapid 

flash) 

              4.

 Repeat the steps of 11-a to add new card. 

 

12. Turning Anti-Tamper Alarm Function ON/OFF 

1.

 Enter programming mode 

2.

 Press

6 (Right Yellow LED rapid flash) 

3.

 Press 01 (1 beep, Right Yellow LED stay on) – function OFF 

Press 02 (1 beep, Right Yellow LED stay on) – function ON 

4. 

Press # (1 beep , Right Green LED stay on) back to standby mode   

 

     

  13. Turning Doorbell Alarm Function ON/OFF 

         

1.

 Enter programming mode 

         

2.

 Press

2 (Right Yellow LED rapid flash)   

 3.

 Press 01 (1 beep, Right Yellow LED stay on) – function OFF 

                Press 02 (1 beep, Right Yellow LED stay on) – function ON 

           

4. 

Press # (1 beep , Right Green LED stay on) back to standby mode   

 

     

 

14. Reseting the Master Code to Default Value 

       

   Turn off the power 

 Press # continuously, and energized (1 beep) the 

master code is reset to default value. 

Содержание DG-800

Страница 1: ...ockout Function The controller will lockout for 60 seconds after entering 5 times invalid codes or cards The keypad doesn t beep during the period of time 5 Controller with keypad sound avoids incorre...

Страница 2: ...ise free environment Keypad Backlight 12 digits 0 9 Input 2 contacts for Request To Exit button 1 contact for door reed switch Output 2 relays N O N C Com Dry Contact LED indicator 2 LED indicators di...

Страница 3: ...tay On The slot position of second relay is available The slot position of second relay is unavailable Beep Standby 1 Beep Valid card key press enter programming mode 3 Beeps Invalid card incorrect PI...

Страница 4: ...to prevent reading range reduction at the card reader 2 It is suggested to use 22 26 AWG insulation wire 3 Exit button is at N O contact 4 With CE qualification EMC specification 5 The door strike or...

Страница 5: ...ws the keypad to be programmed to grant access with either Proximity Card only PIN or Proximity Card Proximity card and PIN 1 Enter programming mode 2 Press 0 Right Yellow LED rapid flash 3 Press 00 1...

Страница 6: ...ode 7 Adding a Proximity Card and PIN to Relay 1 a 1 Enter programming mode to select slot position 000 999 Left Green LED stay on Right Yellow LED rapid flash to indicate the slot position is availab...

Страница 7: ...eps of 8 a to add new card 9 Changing Master Code 1 Enter programming mode 2 Press 3 Right Yellow LED rapid flash 3 Enter 5 digit master code twice e g 45678 45678 1 beep Right Yellow LED stay on 4 Pr...

Страница 8: ...on is unavailable 3 Press 1 beep Left Green LED stay on Right Yellow LED rapid flash 4 Repeat the steps of 11 a to add new card 12 Turning Anti Tamper Alarm Function ON OFF 1 Enter programming mode 2...