V. Operation Instruction
1. Master Code
The master code comprises a five-digit number and is used to perform
programming functions of the digital keypad and cannot be used for access
i.e. it cannot be the same as other PINs. The default master code is set as
12345. Under normal operation the keypad is used for entering PIN to gain
access. In the programming mode the keypad can be used to add/delete
PINs, set relay strike time and other operation functions.
2. Entering Programming Mode
Enter the master code twice (12345 12345) to enter programming mode (1
long beep, Right Yellow LED stay on).
3. Setting the Access Mode
The dual authentication feature allows the keypad to be programmed to
grant access with either Proximity Card only, PIN or Proximity Card,
Proximity card and PIN.
1.
Enter programming mode
2.
Press
*
0 (Right Yellow LED rapid flash)
3.
Press 00 (1 beep, Right Yellow LED stay on) for Proximity Card Only
Press 01 (1 beep, Right Yellow LED stay on) for Proximity Card or PIN
Press 02 (1 beep, Right Yellow LED stay on) for Proximity Card + PIN
4.
Press # (1 beep , Right Green LED stay on) back to standby mode
4. Setting the Relay Strike Time
The relay strike time determines the amount of time that the door remains
unlocked after a valid proximity card or PIN is entered.
*
NOTE: For both Relay 1 & Relay 2, enter 00 will set the relay strike
time to 0 second (relay set to toggle mode).
1.
Enter programming mode
2.
Press
*
1 for Relay 1 (Right Yellow LED rapid flash
Press
*
5 for Relay 2 (Right Yellow LED rapid flash)
3.
Press 00~99 (1 beep, Right Yellow LED stay on)
4.
Press # (1 beep Right Green LED stay on) back to standby mode