Gianni Industries DG-800 Скачать руководство пользователя страница 5

 

Copyright © Gianni Industries, Inc. All rights reserved.   
P-MU-DG-800 Ver. B  Published: 2010.11.22                                                                          
Page: - 5 -/ 8

 

V. Operation Instruction 

 

1. Master Code 

         

 The master code comprises a five-digit number and is used to perform 

programming functions of the digital keypad and cannot be used for access 
i.e. it cannot be the same as other PINs. The default master code is set as 
12345. Under normal operation the keypad is used for entering PIN to gain 
access. In the programming mode the keypad can be used to add/delete 
PINs, set relay strike time and other operation functions. 

 

2. Entering Programming Mode 

Enter the master code twice (12345 12345) to enter programming mode (1 
long beep, Right Yellow LED stay on). 

 
       

3. Setting the Access Mode 

           

The dual authentication feature allows the keypad to be programmed to 
grant access with either Proximity Card only, PIN or Proximity Card, 
Proximity card and PIN. 

 1.

 

Enter programming mode 

2.

 Press

0 (Right Yellow LED rapid flash) 

3.

 Press 00 (1 beep, Right Yellow LED stay on) for Proximity Card Only 

    Press 01 (1 beep, Right Yellow LED stay on) for Proximity Card or PIN 
    Press 02 (1 beep, Right Yellow LED stay on) for Proximity Card + PIN 

4.

 Press # (1 beep , Right Green LED stay on) back to standby mode 

 

       

4. Setting the Relay Strike Time 

           

  The relay strike time determines the amount of time that the door remains 

unlocked after a valid proximity card or PIN is entered. 

         

NOTE: For both Relay 1 & Relay 2, enter 00 will set the relay strike 

time to 0 second (relay set to toggle mode). 

1.

 Enter programming mode 

         

2.

 Press

1 for Relay 1 (Right Yellow LED rapid flash 

              Press

5 for Relay 2 (Right Yellow LED rapid flash) 

         

3.

 Press 00~99 (1 beep, Right Yellow LED stay on) 

         

4.

 Press # (1 beep Right Green LED stay on) back to standby mode 

 

Содержание DG-800

Страница 1: ...ockout Function The controller will lockout for 60 seconds after entering 5 times invalid codes or cards The keypad doesn t beep during the period of time 5 Controller with keypad sound avoids incorre...

Страница 2: ...ise free environment Keypad Backlight 12 digits 0 9 Input 2 contacts for Request To Exit button 1 contact for door reed switch Output 2 relays N O N C Com Dry Contact LED indicator 2 LED indicators di...

Страница 3: ...tay On The slot position of second relay is available The slot position of second relay is unavailable Beep Standby 1 Beep Valid card key press enter programming mode 3 Beeps Invalid card incorrect PI...

Страница 4: ...to prevent reading range reduction at the card reader 2 It is suggested to use 22 26 AWG insulation wire 3 Exit button is at N O contact 4 With CE qualification EMC specification 5 The door strike or...

Страница 5: ...ws the keypad to be programmed to grant access with either Proximity Card only PIN or Proximity Card Proximity card and PIN 1 Enter programming mode 2 Press 0 Right Yellow LED rapid flash 3 Press 00 1...

Страница 6: ...ode 7 Adding a Proximity Card and PIN to Relay 1 a 1 Enter programming mode to select slot position 000 999 Left Green LED stay on Right Yellow LED rapid flash to indicate the slot position is availab...

Страница 7: ...eps of 8 a to add new card 9 Changing Master Code 1 Enter programming mode 2 Press 3 Right Yellow LED rapid flash 3 Enter 5 digit master code twice e g 45678 45678 1 beep Right Yellow LED stay on 4 Pr...

Страница 8: ...on is unavailable 3 Press 1 beep Left Green LED stay on Right Yellow LED rapid flash 4 Repeat the steps of 11 a to add new card 12 Turning Anti Tamper Alarm Function ON OFF 1 Enter programming mode 2...

Отзывы: