Gianni Industries DG-800 Скачать руководство пользователя страница 3

 

Copyright © Gianni Industries, Inc. All rights reserved.   
P-MU-DG-800 Ver. B  Published: 2010.11.22                                                                          
Page: - 3 -/ 8

 

III. Indicator Status & Default Setting Parameters 

Beep & LED Indication:

 

 Mode  Signal 

Status 

LED 

Standby 

Right Green Stay On Power on, Standby 

Green On 

First relay active 

Red On 

Second relay active 

Programming 

Yellow Stay On 

Enter programming mode 

Green Stay On 

Red Stay On 

The slot position of first relay is available. 

The slot position of first relay is unavailable. 

Green Stay On 

Red Stay On 

The slot position of second relay is available. 

The slot position of second relay is unavailable.

Beep 

Standby 

1 Beep 

Valid card, key press, enter programming mode

3 Beeps 

Invalid card, incorrect PIN 

Programming 

1 Beep 

Correct input data, exit programming mode 

3 Beeps 

Incorrect input data, other incorrect operation, 

duplicated card setting 

 

 

Factory Default Setting:

 

Access Mode 

Proximity Card Only 

Format All 

Bits 

Card Storage (MAX. 1000+10 pcs) 

None   

Master Code 

12345 (5 digits) 

Alarm Function (All) 

Function disabled 

Relay Strike Time (Time Delay Setting) 

5 seconds 

Pressed Key Time Delay 

5 seconds (Fixed) 

PIN Code Input Waiting Time 

5 seconds 

Programming Mode Time Delay 

25 seconds (Fixed) 

 

 

 

Содержание DG-800

Страница 1: ...ockout Function The controller will lockout for 60 seconds after entering 5 times invalid codes or cards The keypad doesn t beep during the period of time 5 Controller with keypad sound avoids incorre...

Страница 2: ...ise free environment Keypad Backlight 12 digits 0 9 Input 2 contacts for Request To Exit button 1 contact for door reed switch Output 2 relays N O N C Com Dry Contact LED indicator 2 LED indicators di...

Страница 3: ...tay On The slot position of second relay is available The slot position of second relay is unavailable Beep Standby 1 Beep Valid card key press enter programming mode 3 Beeps Invalid card incorrect PI...

Страница 4: ...to prevent reading range reduction at the card reader 2 It is suggested to use 22 26 AWG insulation wire 3 Exit button is at N O contact 4 With CE qualification EMC specification 5 The door strike or...

Страница 5: ...ws the keypad to be programmed to grant access with either Proximity Card only PIN or Proximity Card Proximity card and PIN 1 Enter programming mode 2 Press 0 Right Yellow LED rapid flash 3 Press 00 1...

Страница 6: ...ode 7 Adding a Proximity Card and PIN to Relay 1 a 1 Enter programming mode to select slot position 000 999 Left Green LED stay on Right Yellow LED rapid flash to indicate the slot position is availab...

Страница 7: ...eps of 8 a to add new card 9 Changing Master Code 1 Enter programming mode 2 Press 3 Right Yellow LED rapid flash 3 Enter 5 digit master code twice e g 45678 45678 1 beep Right Yellow LED stay on 4 Pr...

Страница 8: ...on is unavailable 3 Press 1 beep Left Green LED stay on Right Yellow LED rapid flash 4 Repeat the steps of 11 a to add new card 12 Turning Anti Tamper Alarm Function ON OFF 1 Enter programming mode 2...