GIA Giatsu GIA-PC-09P15 Скачать руководство пользователя страница 12

D

FANMODE 

When using the appliance in this mode, the air hose does not need to be attached. 

To set this mode correctly: 

•  Press the  M  button a number of times until  the :: ::  symbol appears. 
•  Select the required fan speed by pressing the �  bullan. 

Three speeds are available: 

f==l 

L.!] 

1--=l 

C:J 

Maximum speed: 

far maximum fan power 

Medium  speed: 

reduces  noise  levels  but  still 

maintains a good level of comfort 

Low speed: 

far silent operation 

11 

HEA T MODE  (only the heat pump model have this function) 

To set this mode correctly: 

•  Press the  M  button a number of times until the 

�+; 

symbol appears. 

•  Select the target temperature 13-27

º

C (55-81

º

F) by pressing the  /\  orV  button until the corres­

ponding value is displayed. 

•  Select the required fan speed by pressing the 

e%> 

button. 

Three speeds are available: 

• 

Maximum  speed:  to achieve the !argel temperature 

as rapidly as possible. 

Medium  speed:  reduces noise levels but still maintains 

a good level of comfort . 

Low speed:  far silent operation. 

•  Water is removed from the air and collected in the tank . 

•  When the tank is full, the appliance shuts down and" 

Fe" 

(full tank)  appears on the display. 

The tank cap mus! be extracted and emptied. 

Run off all water left into a basin. 

•  When all the water has been drained, pul the cap back in place. 
•  When the tank has been emptied, the appliance starts up again. 

--

--

--

• 

-

,  ,•r

e  • 

�·, 

-•-

-

,.� 

-

N.B.- When operating in very cold rooms, the appliance defreezes automatically, momentarily interrupting  normal operation. 

"Le" 

appears  on the display.  During this operation, it is normal far the noise made by  the appliance to change. 

- In this mode, you may have to wait far a few minutes befare the appl iance starts giving out hot air. 
- In this mode, the fan may operate far short periods, even though the set temperature has already been  reached. 

DRYMODE 

Ideal to reduce room humidity (spring and autumn,  damp  rooms,  rainy periods, etc). 

In dry mode, the appliance should  be prepared in !he same way as far cool mode, 

with the air exhaust hose attached to enable the moisture to be discharged outside. 
To set this mode correctly: 

•  Press the  M  button a number of times until the  dh symbol  appears. 

•  Select the required fan speed by pressing the  �  bullan. 

Three speeds are available: 

Maximum speed: 

to achieve the best 

dehumidify effect. 

Medium speed: 

can reduce noise level but still 

maintances a better dehumidify effect. 

Low speed: far silent operation but weaken the 

dehumidify effect relatively. 

10 

dh 

Содержание Giatsu GIA-PC-09P15

Страница 1: ......

Страница 2: ...4 Description Of The Display Screen 5 Operating From The Control Panel 5 Self diagnosis 8 Manual of Remate control 9 Tips Far Correct Use 12 Water Drainage Method 12 Cleaning 14 Start End Of Season O...

Страница 3: ...sulphur Do not install near sour ces of heat Keep the appliance at least 50 cm away from flammable substances alcohol etc or pres surised containers eg aerosol cans Do not rest heavy or hot objects o...

Страница 4: ...erials to be recove red to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled d...

Страница 5: ...le 6 Castors 7 Control panel 8 lntake grille 9 Air exhaust hose housing 10 Condensar drain 11 Power cable 12 Air exhaust hose 13 Hose outlet 14 Hose inlet 15 Castor locks 16 Suckers 17 Window slider 1...

Страница 6: ...ndow ar French window Adjust the length of the hose to reach the window Make sure the air exhaust hose is unobstructed Open the window ar French window slightly and position the outlet fig 2 lf you ha...

Страница 7: ...ol 6 Temperature indicator OPERATING FROM THE CONTROL PANEL The control panel is on the top of the appliance enables you to manage part functions without remate controller but to fully exploit its pot...

Страница 8: ...ailable Maximum speed to achieve the target tempe rature as rapidly as possible Medium speed reduces noise levels but still maintains a good level of comfort Low speed for silent operation u L I The m...

Страница 9: ...ng the appliance in this mode the air hose does not need to be attached To set this mode correctly Press the M button a number of times until the symbol appears Select the required fan speed by pressi...

Страница 10: ...number of malfunctions Error messages are displayed on the appliance display 1F IS DISPLAYED 111 Low TEMPERATURE frost prevention PROBE FAILURE sensor damaged 111 FULL TANK safety tank full WHAT SHOU...

Страница 11: ...en legislation as they are harmful to the environment TURNING THE APPLIANCE ON Plug into the mains socket then the appliance is standby Press he button to make he appliance turn on The las function ac...

Страница 12: ...play The tank cap mus be extracted and emptied Run off all water left into a basin When all the water has been drained pul the cap back in place When the tank has been emptied the appliance starts up...

Страница 13: ...s another 1 C alter 2 hours and then keeps the same in following period Switch the unit of temperatura In cooling or heating mode press he C F bullan can change he unit of temperature Far example Befa...

Страница 14: ...use the appliance outdoors Make sure the air conditioner is standing on a level surface if necessary place the castor locks under the front wheels WATER DRAINAGE METHOD clase doors and windows curtain...

Страница 15: ...from he front until no more water drains from the outlet Restar he air conditioner by pressing he on off bullan Ensure that he unit is in COOL DRY or HEAT mode The compressor will start approximately...

Страница 16: ...ance v Never spray insecticide liquids or similar CLEANING THE AIR FILTERS To keep your air conditioner working efficiently you should clean the filter every week of operation The evaporator filter ca...

Страница 17: ...cap fig 32 Run off all water left into a basin When all the water has been drained put the cap back in place Clean the filter and dry thoroughly before putting back TECHNICAL SPECIFICATIONS Mains vol...

Страница 18: ...e technical specification of he appliance is not adequa te for he room in which it is located airfilter clogged he interna compressor safety device prevents the applian ce from being restarted until t...

Страница 19: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Отзывы: