6.10 Medium setting
For this purpose, dimensionless primary measured values are assigned to the "Start of
range" and "End of range" parameters, which are measured by the instrument at
standstill of the medium (0 cm/s)
and maximum value of the flow (adjustable with "Max velocity" or "Max flow rate").
Since the characteristic curve between these two points
is generally not a straight line, the curvature of the characteristic curve can be set with
the "Curve" parameter.
For "Start of range" the value is recorded when the flow stops (0 cm/s) and for "End of
range" the value is recorded when the flow equals the value = "Display value". Then
the value "Display value" must be entered manually. The device adjustment character-
istic is automatically adjusted with the help of these parameters.
6.11 Display
By selecting the "Display" configuration, the positioning of the display can be changed.