HD51.3D…
- 5 -
V2.0
2
TECHNICAL SPECIFICATIONS
Models in technopolymer
HD51.3D
[P][1][4][7][A][R]
Models in aluminium alloy
HD51.3D
[4][A]
R-AL
Wind speed
Sensor
Ultrasounds
Measuring range
0…85 m/s (versions without T/RH)
0…75 m/s (versions with T/RH)
0…80 m/s
Resolution
0.01 m/s
Accuracy
±
0.2 m/s or ±
2% of measure, the greatest (0…65
m/s)
± 3% of measure (>
65
m/s)
Wind direction
Sensor
Ultrasounds
Measuring range
0…359.9°. In order to avoid oscillations of the analog output
around 0°, the extended range 0…539.9° can be set.
Resolution
0.1°
Accuracy
± 2° RMSE (wind speed > 2 m/s)
Temperature
(only models in technopolymer, option
17
is required)
Sensor
Pt100
-
Measuring range
-40…+70 °C
-
Resolution
0.1 °C
-
Accuracy
± 0.15 °C ± 0.1% of measure
-
Relative humidity
(only models in technopolymer, option
17
is required)
Sensor
Capacitive
-
Measuring range
0…100%RH
-
Resolution
0.1%
-
Accuracy (@ T = 15…35 °C)
±
1.5%RH (0…90%RH),
±
2%RH (remaining range)
-
Accuracy (@ T = -40…+70 °C)
±
(1.5 + 1.5% of measure )%RH
-
Atmospheric Pressure
(option
4
is required)
Sensor
Piezoresistive
Measuring range
300…1100 hPa
Resolution
0.1 hPa
Accuracy
± 0.5 hPa @ 20
°C
Global solar radiation
(only models in technopolymer, option
P
is required)
Sensor
Thermopile
-
Measuring range
0…2000 W/m
2
-
Resolution
1 W/m
2
-
Accuracy
Class C pyranometer
according to ISO 9060:2018
-
C Tilt angles
(option
A
is required)
Resolution
0.05°
Accuracy
± 1°
Heating
(option
R
is required, always included in the models in aluminium alloy)
Heater power supply
24 Vdc ± 10%
Heater power consumption
15 W
80 W
Содержание DeltaOHM HD51.3D Series