![GHM Delta OHM HD52.3D Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ghm/delta-ohm-hd52-3d-series/delta-ohm-hd52-3d-series_operating-manual_2220406011.webp)
HD52.3D…
- 11 -
V2.2
5
INSTALLATION
To install the instrument, pass the connection cable inside the support mast and connect the
19-pole M23 female connector of the cable to the 19-pole M23 male connector situated at the
bottom of the instrument. Ensure connection stability by tightening the connector external nut.
Align the instrument to the desired direction (see par. 5.1 “Alignment”), then fix it on the sup-
port mast by tightening the cable tie at the bottom of the instrument.
The support mast, having 40
mm maximum outer diameter and 36
mm minimum inner diame-
ter, should be positioned on a stable surface.
The instrument should be installed vertically and in an open area, far from obstructions located
in the vicinity that might alter the natural air flow. Any close objects (such as buildings, trees,
pylons, etc.) should be at a distance equal to at least ten times their height.
In the presence of close objects, it is advisable to place the instrument at a height of 10 m
(except version with rain gauge option).