IV –Treatment Room Implementation
1.
Electricity Inlets (Optional If Pipeless Massage Pump included).
Requirements: costumer must provide electric source under
6mA GFCI
circuit breaker
Electric power:
Europe 220V-50Hz. GFCI circuit breaker 6.00 A sens. 6.00mA.
USA 100V-60Hz. GFCI Circuit breaker 12.00 A sens. 6.00mA.
Electrical power cable inlet:
for easy connection leave free coil of 1.00 meter out of the ground.
Europe single Phase + N Ground / 3 wire cable 3x 1.5mm2
USA single Phase + N Ground / 3 wire cable 3x 2.5mm2
2.
Water Inlets.
Requirements:
Hot and cold water / costumer provide water inlets via a serial combination of DN ½” short ball
valve, DN ½” filters and DN ½” flexibles connections diameter length 40Cm - 16”.
Water Service Pressure: Min 0.8 Bars Max 2.00Bars.
Water Hardness TH (°F): 7 – 10
Min/Max Warm Water Temperature: 35°C /50°C. 95°F/122°F
Cold Water Temperature: 5° to 15°C. 41°F to 60°F
Drain DN 40mm - 1”1/2.
Water Drainage flow: 25 L/Min.
!! Important Notice: the maximum allowed Pedispa service pressure is 2.00 bars!!
Содержание Pedispa Compact
Страница 6: ...6 Unfolded position fig 2 Full Spread Position fig 3...
Страница 7: ...7 III Before Installation 1 Over All Dimension Over All Dimension front view fig 4 Metric Inch...
Страница 13: ...13 Perspective of the Base frame fixation and inlets implementation drawing fig 11...
Страница 19: ...19 Annex 1 Space requirements implementation example drawings Corner space Implementation example fig 16...
Страница 20: ...20 Room space dual Pedispa compact Implementation example fig 17...
Страница 21: ...21 Room space Quadruple Pedispa compact Implementation example fig 18...
Страница 22: ...22 Room space Pedispa compact Circular Implementation Centralized single backwash station example fig 19...