10. Attachment method
■ Panel process drawing
1. Drill a hole in the attachment panel as shown in the figure below.
Assemble the controller body and the front cover and fix them using an M4 screw and nut.
2. Use an attachment panel with a thickness of 2mm or less.
11. Troubleshooting
•
Confirm that the motor is connected correctly.
•
Ensure that the operation switch is in the 「RUN」position.
•
Check the connection of the AC power supply.
Part tocheck
Problems
The value is not displayed on
the display unit when the
power is supplied.
The motor does not rotate.
There is abnormality or excessive
vibration in the motor operation.
The motor rotates,but the speed
cannot be changed.
The motor does not run
immediately.
The speed cannot be changed.
•
Determine if the product is overloaded.
•
If the rotation speed is not displayed on the display unit, check
for an abnormality in the TG signal of the motor or for incorrect wiring.
•
Check to determine if the acceleration time is excessively long.
•
Cancel the lock setting. (Unlock the product.)
•
Check to determine whether the motor is affected by external noise.
•
The combination of the motor and speed controller may be incorrect .
11
2-M4 or 2-
Φ
4.5
Attachment Panel
2-M4 screw