8. Names and functions of each part
9. How to use and wire
9-1 Connection method
▶ Forward operation wiring
▶ Reverseoperation wiring
1) Connect the motor connector
2)
Connect the ②COM and ③CW terminals.
3)
Connect the AC power to the ⑥ and
⑦ terminals
1) Connect the motor connector
2) Connect the ②COM and ③CCW terminals.
3)
Connect the AC power to the ⑥ and
⑦ terminals
7
Display unit
External operation switch
Dial
Operation switch
[ Displays the rotation speed
and parameters ]
[ When you movethe operation
switch to RUN, the motor rotates.
when you movethe operation
switch to STAND-BY, the motor stops. ]
[ Changes the rotation speed or
parameters ]
[ Thisis used for starting or stopping
external operation. / When it is set
to ON, the motor operates.
when it is set to OFF, the motor
stops. ]
Motor terminal block
[ Thisis used toconnect the lead
wire to the motor]
Protective ground terminal
Power terminal bock
[ Connects the AC power supply]
Motor connector block
[ Connects the motor connector ]
Motor connector
Motor connector