Art.-Nr.: 700 000/710 000/730 000/740 000/741000
GfS-Day Alarm
7
MA_GfS-Tagalarm_0515_GB
GfS Day Alarm INOX GfS Art. No 740 000 with cable reed contact – Terminal diagram
TECHNICAL DATA
Art.-Nr.: 740 000
1
2
3
4
5
6
7
8
9
10
3
4
5
6
2
1
3
4
5
6
7
8
2
1
Jumper 1 Pos. 1–2
external key switch
reed contact
External access control system
floating contact
external key switch
NO
NC
COM
24 V
GND
Key switch parallel to internal key switch
Clamp
Functions
1–3
Floating relay, 30 V/0,5 A max
4
8 – 12 V/DC (max 13 V)
5
GND
6 + 7
Parallel to internal key switch
To be connected with GND
7 + 8
External key switch
9 + 10
Reed contact
GfS Day Alarm with receiver requires jumper
Functions DIP switch
Standard hold open time 15 sec. (DIP 1-3 OFF)
DIP 1 ON Hold open time + 5 sec.
DIP 2 ON Hold open time + 10 sec.
DIP 3 ON Hold open time + 20 sec.
Like this hold open times may be realized in 5 sec. steps from
15 to 50 sec.
DIP 4 ON Silent Alarm
DIP 5 ON Automatic alarm switch-off after 3 min.
DIP 6-8 Reserve