GfS-Day Alarm

  

Art.-Nr.: 700 000/710 000/730 000/740 000/741000

2

MA_GfS-Tagalarm_0515_GB

GENERAL DESCRIPTION

INSTALLATION INSTRUCTIONS

The GfS Day Alarm is a cost-effective and simple  solution to secure emer-
gency exits. The opening status of the emergency exit door is monitored by 
a radio or cable reed contact.
When walking through the door an accoustic  alarm (95dB) and flash-light 
is triggered. Authorized persons may deactivate the GfS Day Alarm by the 
integrated key switch.
If somebody forgets to close the door after an authorised walk-through, an
acoustic intervalic alarm is triggered 15 sec. after the emergency exit door 
has been opened.The green LED flashes. 

As soon as the door is closed, the red LED illuminates again, the interval
tone expires and the device is activated again.

By using the key switch, it is possible to deactivate the GfS Day Alarm for 
a long period.
The actual status of the GfS Day Alarm is indicated by a green and red LED.
The battery-operated GfS Day Alarm LC, however, does not integrate a 
flash light. The GfS Day Alarm LC which integrates battery monitoring just 
operates in combination with cable reed contacts.
All versions incorporate an automatic alarm switch-off, a floating-contact 
for alarm transmissions and an interface to connect external access control 
systems.

Open GfS Day Alarm unit. Remove red plastic cap and pull out the panel 
with the LEDs and profile cylinder. Mount the GfS Day Alarm unit with the 
screws. 

The two upper screws have to be screwed in first and the unit be hung in. 
To secure the unit the two lower screws have to be screwed in. Install the 
reed contact at the door (installation depends on the version that was or-
dered).

Start-up after first installation

Before connecting the power supply please make sure that the door and 
thus the reed-contact is closed.

Delivery state

When installed for the first time the GfS Day Alarm is deactivated.

Battery operated versions 

Please insert the battery first.

Radio reed contact

GfS-Day Alarm

Key Switch outdoor

Reed contact

GfS Day Alarm

Display panel

Key switch

Junction box

Содержание Day Alarm

Страница 1: ...41000 A r t N r Art Nr 700000 730000 A r t N r GfS Gesellschaft f r Sicherheitstechnik mbH Tempowerkring 15 D 21079 Hamburg Tel 0 40 79 01 95 0 Fax 0 40 79 01 95 11 info gfs online com www gfs online...

Страница 2: ...n and red LED The battery operated GfS Day Alarm LC however does not integrate a flash light The GfS Day Alarm LC which integrates battery monitoring just operates in combination with cable reed conta...

Страница 3: ...n and remove it Open the door and walk through Close the door again The red LED shines and the the GfS Day Alarm is activated again In case that nobody walks through the door the green LED shines for...

Страница 4: ...rops out that means in case of an alarm COM and NC are closed in all other cases COM and NO are closed Jumper set Pos 1 2 After 3 minutes the sir ne is switched off automatically The flash light remai...

Страница 5: ...e till the GfS Day Alarm is reset Pos 2 3 The siren and falsh light is permanently activated in case of an alarm Jumper 2 Pos 1 2 For cable reed contact Power plug GfS Art No 700 000 scope of delivery...

Страница 6: ...n opened while the GfS Day Alarm is armed Buzzer resounds DIP 4 is OFF Flash light is activated Red LED flashes quickly 0 3 sec on 0 3 sec off Relay switches off COM and NC are connected Buzzer expire...

Страница 7: ...ey switch parallel to internal key switch Clamp Functions 1 3 Floating relay 30 V 0 5 A max 4 8 12 V DC max 13 V 5 GND 6 7 Parallel to internal key switch To be connected with GND 7 8 External key swi...

Страница 8: ...ched on for approx 15 sec Then the LED expires and the GfS Day Alarm operates in a stand by mode while waiting for external signals During the permanent opening mode the green LED flashes every 60 sec...

Страница 9: ...t function No remote reed contact available Cable reed contact with 2m cable Max distance between reed contact and magnetic counter part between 5 to max 10mm Power supply 9 V block battery in the sco...

Страница 10: ...lected transmitters without having to reset the receiver totally Push the program button for a minimum of 3 seconds The light signal blinks Operate the transmitter that shall be deleted This is confir...

Страница 11: ...the operator Version GfS Day Alarm with external power supply GfS Art No 700 000 GfS Day Alarm battery operated GfS Art No 710 000 GfS Day Alarm with integrated power supply GfS Art No 730 000 GfS Day...

Страница 12: ...ates correctly Pecularities of the building site All GfS Day Alarms are accessible The GfS Day Alarm has been tested and approved Version GfS Day Alarm with external power supply GfS Art No 700 000 Gf...

Страница 13: ...Art Nr 700 000 710 000 730 000 740 000 741000 GfS Day Alarm 13 MA_GfS Tagalarm_0515_GB NOTES...

Страница 14: ...rn back the key into the middle position and remove it Close the door or in case that the door is already closed wait for approx 15 sec The LED shines red the GfS Day Alarm is activated red LED shines...

Страница 15: ...s max 1 sec 3x press each time max 1 sec flashes shines for approx 4 sec expires Deleting single senders Description Programming button LED Press programming buttom for at least 3 sec Operate the radi...

Страница 16: ...GfS Gesellschaft f r Sicherheitstechnik mbH Tempowerkring 15 D 21079 Hamburg Tel 0 40 79 01 95 0 Fax 0 40 79 01 95 11 info gfs online com www gfs online com...

Отзывы: