GfS-Day Alarm
Art.-Nr.: 700 000/710 000/730 000/740 000/741000
6
MA_GfS-Tagalarm_0515_GB
GfS Day Alarm INOX GfS Art. No 740 000 with radio reed contact – Terminal diagram
TECHNICAL DATA
Art.-Nr.: 740 000
Mains supply
Door alarm secured, reed contact is closed.
Receiver is closed.
In case that cable reed contacts are connected ( also in case of battery
operation) jumper 1 must be set on position 1+2
Red LED shines
Relais is pulled (COM and NO connected)
Authorized use
Turn key in internal key switch or use the external key switch (clamp 6)
briefly (< 5 sec.)
Green LED shines permanently.
The alarm remains deactivated till the door is closed again.The LED
shines red again.
If the door has not been opened for 15 sec the alarm is automatically
activated again. The LED shines red. If the door has not been closed after
15 sec. a door-too-long-open-alarm is triggered.
Door-too-long-open-alarm
Relais switches off (COM and NC connected)
Green LED flashes slowly (every 1,5 sec). Buzzer gives alarm every 3 sec.
for about 200ms (short beep).
When the door is closed again, the GfS Alarm is activated again. The LED
shines red again. The hold-open time might be extended by turning again
clockwise to max. end stop.
Alarm
The reed contact has been opened while the GfS Day Alarm is armed.
Buzzer resounds (DIP 4 is OFF)
Flash light is activated
Red LED flashes quickly (0,3 sec. on/0,3 sec. off)
Relay switches off (COM and NC are connected)
Buzzer expires after 3 min. while DIP 5 is ON. Otherwise the buzzer
resounds permanently.
To quit: Only by operating the key switch (internal or external). Not
possible with external opening contact.
Permanent opening
Insert the key and turn clockwise as far as it will go. The green LED is
switched on. Leave in this postion until the LED switches off (about 5
sec.). After that turn key anticlock and remove. Now the door can be
freely used without triggering the alarm. The green LED flashes, which
signals that the GfS Day Alarm is permanently deactivated. To activate
the GfS Day Alarm again, briefly turn key clockwise as far as it will go.
The green LED shines. Now turn key anticlockwise and remove it. Close
the door or if the door is closed already, wait 15 seconds. Now the LED
shines red and the system is armed again.
External switch
In case that the GfS Day Alarm receives a permanent external release
signal, the GfS Alarm is activated again after 20 sec. There is no
permanent external release feature available.
1
2
3
4
5
6
7
8
9
10
external key switch
Jumper for radio reed contact
External access control system
floating contact
external key switch
NO
NC
COM
12 V
GND
Key switch parallel to internal key switch
3
4
5
6
7
8
2
1