Fusion process
11
Next paragraphs describe step by step the interactions with the
electrofusion unit.
2.2 Switching On
Before connecting the machine to the power source, please
read the chapter 6 ‘Technical characteristics‘ and check the
input voltage (100V-130V). If a generator is used, this has to be
started before connecting the electro-fusion unit and must
supply a constant output voltage! Any sudden changes could
compromise the correct welding result and/or damage the
control unit.
Connect the machine to the power mains or generator (100v-
130V) when the generator is already started. At power on the
display shows the machine information: machine type, software
version and serial number.
2.3 Material selection
As soon as the scanner is enabled during the power on, select
the plastic material: the MSA 2 CF can weld PE, PP-R,
PP/PVDF or PB INSTAFLEX fittings. As the fusion parameters
change depending on the material, the user has to set the
proper one. This shall be done reading with the scanner the
desired barcode, out of the 4 shown below