Operating Instructions MSA 2 CF
Fusion process
15
code is entered, blocking the acquisition of the fusion
parameters.
2.6 Enter fusion data
After that, you can insert the fusion parameters reading the
barcode information with the scanner.
If the barcode cannot be read with a scanner for any reason, the
data can be entered manually.
In case of manual mode, the machine works in different ways,
depending on the material selection.
If the material selection is PE or PP-R, then time and voltage
values must be entered, pressing the START/OK ( I ) button to
go in “edit” mode and then using (
) and (
) to select the
required digits and (
) (
) to change field. Once the values are
entered, must be pushed START/OK ( I )
If the mode is PP, the manual mode is based on a list of
selectable items the user can see pressing the START button.
With (
) and (
) he can choose the fitting, confirming with the
START/OK button.
SeaDrainplus
d= 1. 5” x4
12/06/12 15:50
If the mode is PB (INSTAFLEX), then the manual mode is also
based on a list of selectable items the user can see pressing the
START button. With (
) and (
) he can choose the fitting type,
confirming with the START/OK button.
INSTAFLEX
d125
12/06/12 15:50