background image

page 2 of 8

8350-3 Temperature Transmitter Instructions

3. Electrical Connections

Caution:  Failure to fully open terminal jaws before removing wire may
permanently damage instrument.

Wiring Procedure
1. Remove 0.5 - 0.625 in. (13-16 mm) of insulation from wire end.
2. Press the orange terminal lever downward with a small screwdriver to open

terminal jaws.

3. Insert exposed (non-insulated) wire end in terminal hole until it bottoms out.
4. Release orange terminal lever to secure wire in place.  Gently pull on each wire

to ensure a good connection.

Wiring Removal Procedure
1. Press the orange terminal lever downward with a small screwdriver to open

terminal jaws.

2.  When fully open, remove wire from terminal.

Terminals
1. AUX 1+
2. AUX 2-

System Power/Loop
3.

System Power/Loop 1 +

4.

System Power/Loop 1-

5.

Loop 2+

6.

Loop 2-

Open Collector Output
7.

Output 1+

8.

Output 1 -

9.

Output 2+

10. Output 2-

Preamplifier/Sensor Input
11. Black (Sensr 1 V+)
12. Red (Sensr 1 IN)
13. Silver (Sensr 1 Gnd)
14. Black (Sensr 2 V+)
15. Red (Sensr 2 IN)
16. Silver (Sensr 2 Gnd)

Wiring Tips

:

Do not route sensor cable in conduit containing AC power wiring - electrical
noise may interfere with sensor signal.

Routing sensor cabling in grounded metal conduit may prevent moisture
damage, electrical noise, and mechanical damage.

Seal cable entry points to prevent moisture damage.

When placing two wire ends into a single terminal, solder or crimp ends
together.

2

1

108 mm 
(4.25 in.)

96 mm (3.8 in.)

96mm (3.8 in.)

96 mm

(3.8 in.)

97 mm

(3.8 in.)

56 mm 
(2.2 in.)

41 mm 
(1.6 in.)

96 mm
(3.8 in.)

Optional
Rear Cover

Dimensions

  

  

Panel Mount

Field Mount

Panel  Cutout

92  x 92 mm

(+ 0.8, - 0 mm)

3.6 x 3.6 in.

(+0.031, -0 in.)

82 mm
(3.23 in.)

Output 2-

Output 2+

Output 1-

Output 1+

10

9

8

7

Loop 2-

Loop 2+

System Pwr

Loop -

System Pwr

Loop +

AUX

Power -

AUX

Power +

6

5

4

3

2

1

Snsr 2 Gnd

(SHIELD)

Snsr 2 IN

(RED)

Snsr 2 V+

(BLACK)

Snsr 1 Gnd

(SHIELD)

Snsr 1 IN

(RED)

Snsr 1 V+

(BLACK)

16

15

14

13

12

11

Description
12-24 VDC

12-24 VDC 

±

5%, system power and current loop connections.

Max. loop impedence:  50 

 max @12 V, 325 

 max @ 18 V

 600 

 max. @ 24 V.

Open-collector transistor output programmable as:

High/Low alarm with adjustable hysteresis

Proportional pulse output  (0-400 pulses/min)

Disable (Off) selection

Содержание SIGNET 8350-3

Страница 1: ...rsal Assembly 3 8050 1 Install transmitter base 2 Connect wires to transmitter 3 Close unit and secure with push and twist lock Seal cable entry 1 Installation The transmitter is available in three ve...

Страница 2: ...5 Red Sensr 2 IN 16 Silver Sensr 2 Gnd Wiring Tips Do not route sensor cable in conduit containing AC power wiring electrical noise may interfere with sensor signal Routing sensor cabling in grounded...

Страница 3: ...upply DC 12 24 V Power Supply Power Supply Connection to a PLC with built in power supply PLC Terminals Power Supply Ground Power Supply Channel 2 4 20 mA in Channel 2 4 20 mA in Channel 1 4 20 mA in...

Страница 4: ...CAL 08 01 99 LAST CAL 01 01 99 GF SIGNET LAST CAL 01 01 99 Example To change date first enter CALIBRATE menu Press ENTER button for 2 seconds Press UP UP UP DOWN buttons in sequence Once in CALIBRATE...

Страница 5: ...Low 4secs Loop1 Output 4 20 mA Set 20 C N A High 8secs mA Temperature Output1 Active Low Low Loop2 Output 4 20 mA Loop1 Source Temp1 Temp1 Low High mA Temp1 Temp2 Output2 Active Low Low Last Cal 00 00...

Страница 6: ...page 6 of 8 8350 3 Temperature Transmitter Instructions...

Страница 7: ...page 7 of 8 8350 3 Temperature Transmitter Instructions...

Страница 8: ...1 Aerojet Avenue El Monte CA 91731 2882 U S A Tel 626 571 2770 Fax 626 573 2057 For Worldwide Sales and Service visit our website gfsignet com Or call in the U S 800 854 4090 GEORGE FISCHER GF Piping...