33
Spring
Colour
Max.
Downstream
Pressure (Bar[g])
Adjustment
sensitivity
(Bar/full turn)
Black*
8.5
0.43
Blue
17
0.65
Red
25
1.5
ATTENTION
Default outlet pressure!
At delivery the outlet pressure is set to default.
► The default outlet pressure of the NeoFlow pressure reducing valve with black colour coding of the pilot
valve spring is 3 bar.
Caution
Use of an incompatible NeoFlow pressure reducing valve type!
The manufacturer's specifications regarding the maximum pressure difference between the inlet pressure
and the outlet pressure must be complied with.
► Non-compliance can result in injury as well as material damage to the valve and piping system.
► Only use the NeoFlow pressure reducing valve type that is matched to the pressure range