Setting the parameters of the drive
Slimchain 230 V AC
EN 12
9
Setting the parameters of the drive
Parameters can be set for the drive using the LIN parameter setting adapter
(GEZE mat. no. 179238) and the parameter setting device ST 220 (GEZE mat.
no. 087261). To do this:
X
Open the service cover and insert the parameter setting adapter
X
Connect the drive to 230 V and operate in the “CLOSE” direction
X
Wait until the drive has reached the “CLOSE” end position
X
Carry out parameter setting using ST 220
GN green
BN brown
WH white
LIN
+24 V
GND
L
B
A
ST 220
Connection cable
ST 220
LIN parameter setting adapter
Pin strip for connecting the
LIN parameter setting adapter
GN
BN
WH
FSE 301
LIN
cable
The possible projection range for the drives is 8-23 mm.
In the case of windows with a projection > 23 mm the drive stroke must be
reduced.
Further information about parameter setting can be found in the inst-
ructions GEZE mat. no. 153523 for the parameter setting device.
10 Operating
modes
Operating mode ventilation
Drive opens at ventilation speed up to ventilation stroke