37
E
N
G
L
I
S
H
The
party function
is used to temporarily exclude the set program (AUTO mode) or the
manual set point (MAN mode) by inserting a different temperature set point for a period
of between 1 and 23 hours.
This function can be used, for example, to extend the comfort period during a supper, a
party, etc.
Press the MODE key for 5 seconds to activate the func-
tion: the symbol
is displayed on the VDU and the set
point value active at that time starts to blink.
The
keys are used to set the new temperature
set point value.
Pressing the MODE key moves on to setting the num-
ber of hours of activation, which is displayed on the
VDU. This regulation is done using the
keys.
Press the MODE key or wait 5 seconds to confirm the
setting made.
When the function is active it is still possible to modify the set point value and the peri-
od of activation in the same way as described above.
The party function remains active until the set period elapses.
The count of the hours is decremented during operation.
It is possible to deactivate the
party function
at any time, restoring the previous mode,
by pressing the MODE key twice for an extended period.
The
holiday function
is used to temporarily exclude the weekly set program (AUTO
mode) or the manual set point (MAN mode) by manually inserting a different temperature
set point for a period of between 1 and 99 days.
This function can be used, for example, to program an economy period during a holiday
and reactivating the program on the day of return.
Party/Holiday function
Содержание GW 20 827
Страница 23: ...Inset time thermostat with relay E N G L I S H...
Страница 45: ...Chronothermostat relais encastrable F R A N A I S...
Страница 67: ...Cronotermostato de rel empotrado E S P A O L...
Страница 89: ...Relais Zeitthermostat f r Unterputzmontage D E U T S C H...
Страница 111: ...Cronotermostat cu releu montaj ncastrat R o m n...
Страница 133: ......
Страница 134: ......
Страница 135: ......