INSTALLATION INSTRUCTIONS
68
The channels available in the programming mode are:
StS (Status)
Used to send to remote devices (for instance the Easy
GSM Remote Control Unit - GW 90 861):
• function type and mode:
• temperature reading (every 15 minutes or each time it
changes).
CdH (Heating command)
Used to send the ON/OFF command to the KNX/EIB
actuators that control the heating system.
CdC (Cooling command)
Used to send the ON/OFF command to the KNX/EIB
actuators that control the air conditioning system.
MAS (
Master
)
Used to send the zone thermostats enabled as “slaves”
the function type (heating/air-conditioning) and mode type
(OFF, Comfort, Precomfort, Economy).
When creating the above listed functions, it is not necessary to select a base unit function
as the link is created automatically.