D
9
GB
F
NL
S
DK
8
Batteries
Not rechargeable. Do not burn. Do not open or swallow. Keep
out of the reach of children. Make sure the battery is inserted
correctly (+/-) and do not short circuit.
Do not dispose of batteries with your household waste. The end user
must recycle all used batteries. Batteries may be returned free-of-
charge to the place of sale or to your local collection point.
Changing the fuse
The time switch is fi tted with an internal fuse.
Always replace the fuse with another fuse of the same type
(T 3.15 A/250 V), never with a fuse with a higher current
rating! This will create a risk of accident, damage the device and
invalidate the warranty
.
Remove the control panel (see: Installation) and carefully lift off fuse
cover
C2
. Replace the spent fuse and put the fuse cover back on.
Technical data
Operating voltage
230 V ~, 50 Hz
Switching capacity
40 W – 400 W, resistive load e.g. incandescent/halogen lamps
Fuse T
3.15
A/250
V
Protection type
IP 20
Permissible ambient temperature
0 °C to +40 °C
Mode of operation
type 1B (EN 60730)
Pollution class
2 (EN 60730)
Battery
CR1025, lithium button cell, 3 V
Reserve power in event of power failure
approx. 50 days
Programs
9 x ON and 9 x OFF, up to 45 switching operations by creating blocks of days
Shortest switching interval
1 min
Installation depth
35 mm
Installation
ø 68 mm fl ush-mounted box
Frame
50 mm x 50 mm
Subject to technical and design changes without prior notice.
Problem Cause
Solution
Fault indicator
B8
is displayed
No power supply?
Check the power supply
Illuminant faulty?
Change illuminant
Spent fuse?
Change fuse
The light does not switch
AUTO mode turned off?
Turn on AUTO mode
ON/OFF at the preset times
Device turned ON/OFF by switch
(B7)
? Check
display
B7
Press switch