EN 16
5 Operating the system
When the SmartFan X is switched on, it takes about 45 seconds before the iris diaphragm opens.
When it is switched off, the motor stops and, about 25 seconds later, the iris diaphragm shuts.
The reaction speed of the iris diaphragm is due to technical reasons and completely normal.
5.1
Use of control modules
When connected to a control module, the SmartFan X switches on when:
• the motion sensor registers that a person is in the room;
• the humidity sensor registers that the set humidity level for the room is exceeded;
• 230 volts reach the „T“ trigger (see Cabling and wiring [A]).
When connected to a control module, the SmartFan X switches off when:
• the motion sensor registers that nobody is in the room;
• the humidity sensor registers that the humidity level is lower than the set level;
• the set time has passed;
• 230 volts are no longer reaching the „T“ trigger (see Cabling and wiring [A]).