![GESTRA ZK 213 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/gestra/zk-213/zk-213_original-installation-instructions_2217873018.webp)
18
Mounting and connecting the
equipment
DANGER
Risk of bruises if the equipment or
component parts fall down.
Always wear protective gear when
working on the equipment.
Use suitable lifting gear when moving
or lifting the equipment and/or
component parts.
Make sure that the equipment cannot
topple over.
To lift the equipment use only the
valve body or the bonnet.
Make sure that nobody is standing
below the lifted equipment.
The protective gear must comprise at least the
following:
Safety helmet to EN 397
Safety footwear to EN ISO 20345
Protective leather gloves to EN 388
For more information on suitable safety clothing and
safety gear refer to the safety data sheet of the fluid
in question.
The lifting gear must be of sufficient strength for
the equipment including the actuator.
For more information on the weight of the
equipment see the attached documents. For more
information on the weight of the actuator see the
documents provided by the actuator manufacturer.
Preparing installation
Remove the transport packaging.
Check the equipment for transport damage.
If you detect any transport damage, please
contact the manufacturer.
When supplied by the factory, the connections may
be sealed off with sealing plugs.
Remove sealing plugs before mounting the
equipment.
Keep the sealing plugs and the packing for
further use.
DANGER
Personnel working on pipes are exposed to
safety risks and may suffer severe injuries,
poisoning or even loss of life.
Make sure that no hot or hazardous
fluid is in the equipment or the pipes.
Make sure that the pipes upstream
and downstream of the equipment are
depressurised.
Make sure that the installation is
switched off and protected against
unauthorised or unintended activation.
Make sure that the equipment and the
pipes have cooled down to room
temperatures.
Wear protective clothing that is
suitable for the fluid and, if necessary,
wear protective gear.
For more information on suitable protective clothing
and safety gear refer to the safety data sheet of the
fluid in question.
Drain pipes until they are empty.
Switch the installation off and protect it against
unauthorised or unintended re-activation.