31
Replacing the sightglass of the sightglass
cover
Remove the Allen screws (35).
Remove the flange (34) from the sightglass (14).
Remove the outer gasket (33).
Remove the water-level gauge (32).
Remove the inner gasket (33).
For the disposal of the gaskets observe the
pertinent on-site regulations concerning waste
disposal.
Attention!
Equipment may leak if the gasket is
damaged.
Replace all gaskets that you loosen
during your work.
Use only new gaskets of the same
type.
Apply heat resistant lubricant to the threads and
bearing faces of the socket-head cap screws.
The lubricant must have the same properties as
OKS
®
217.
Insert a new gasket in the sightglass cover.
Insert a new sightglass.
Put a new gasket on the sightglass.
Screw the socket-head cap screws into the
bores of the flange.
Tighten the socket-head cap screws alternately
and in several steps with a torque of 12 Nm.