21
Replace all gaskets with new ones of the same
type.
Insert a new regulator gasket (28) in the body
(2).
Turn the control unit (4) to the desired position.
Insert the control unit in the body without tilting
it.
Secure the control unit using the four Allen
screws (27).
The torque of the Allen screws depends on the
model.
For models with DN 15 to DN 25, the required
torque is 4 Nm.
For models with DN 40 to DN 65, the required
torque is 7 Nm.
Tighten the Allen screws to the specified torque.
Attach the cover to the body as described in the
section "
Mounting cover
" from page 21.
Mounting cover
Attention!
Equipment may leak if the gasket is
damaged.
It is therefore essential that you
always insert a new gasket before re-
attaching the cover.
Make sure that the cover is not tilted
or skewed when refitted.
Clean the gasket surfaces of the cover and
body.
Apply heat resistant lubricant to the threads and
bearing faces of the screws.
The lubricant must have the same properties as
OKS
®
217.
Put a new body gasket (3) onto the body (2).
Insert the four screws (9) into the bores of the
body.
Refit the cover (7) onto the body such that the
name plate (6) points upwards.