background image

 

 

14 

  

 

Disposing of the equipment 

Technical data 

 

CAUTION 

Environmental damage may be caused by 
poisonous fluid residues. 

 

Before disposing of the equipment 
make sure that it is clean and free of 
fluid residues. 

 

For the disposal of all materials 
observe the pertinent legal regulations 
concerning waste disposal. 

Pressure & temperature ratings 

You can find the values for your equipment on the 
rating plate. 

Weights 

You can find the values for your equipment on the 
rating plate. 

Dimensions 

  

The equipment is made of welded sheet steel. 

 

By way of example, the diagram below 
shows a standard device with flanged end 
and direction of flow from left to right. 

  

PN 

Material 

Flange 

Pipe 

Base 

16 

1.0460 

(P250GH) 

1.0345 

(N) 

1.0425 

(P265GH) 

 

16 

1.4571 (X6CrNiMoTi17-12-2) 

40 

1.0460 

(P250GH) 

1.0345 

(N) 

1.0425 

(P265GH) 

  

You can return the equipment to your contractual 
partner. 

 

Make sure that all harmful substances are 
removed from the equipment. 

 

Pay attention to the instructions in section 
"Transporting the equipment" from page 8. 

 

Pack the equipment in its original packaging or 
in suitable transport packaging. 

The transport packaging must protect the 
equipment from damage in the same way as the 
original packaging. 

 

Send the completed and signed 
decontamination declaration with the 
equipment. The decontamination declaration 
must be attached to the packaging so that it is 
accessible from outside. 

 

  

 

Register the return delivery with your contractual 
partner before returning the equipment. 

  

 

  

Содержание TD

Страница 1: ...Steam Drier Steam Purifier TD Air Drier Air Purifier TP Original Installation Instructions 819479 02 ...

Страница 2: ...tives 8 Storing and transporting the equipment 8 Storing the equipment 8 Transporting the equipment 8 Mounting and connecting the equipment 9 Preparing installation 9 Connecting the equipment 10 Operation 11 After operation 12 Removing external dirt deposits 12 Maintaining the equipment 12 Installing spare parts 12 Putting the equipment out of operation 12 Removing harmful substances 12 Removing t...

Страница 3: ...pment Please note that in addition to the instructions given in this installation operating manual you must also observe all locally applicable rules and regulations concerning the prevention of accidents as well as approved safety guidelines for good professional practice Safety Use for the intended purpose The TD steam drier steam purifier is installed in steam systems The equipment is used to s...

Страница 4: ...sed or unintended activation Make sure that all locally applicable regulations on safety and the prevention of accidents are strictly adhered to The pipes and the equipment must have cooled down to room temperature approx 20 C Risk of minor injuries If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment Before ...

Страница 5: ...lified person must be acquainted with and experienced in the following the pertinent on site rules and regulations for preventing fire and explosions Attention This information warns of a situation leading to property damage working on pressure equipment making pipe connections working with dangerous hot or pressurized fluids Description lifting and transporting loads observing all notes and instr...

Страница 6: ...ction for steam or air outlet 4 Name plate 6 Connection for condensate outlet No Designation 1 Connection for steam or air inlet 2 Connection for steam or air outlet 3 Vent only needed for work by the manufacturer 4 Name plate 5 Inspection hole 6 Connection for condensate outlet 7 Lugs nominal size 200 upwards ...

Страница 7: ...team or air Manufacturer Type designation Min service temperature Max service temperature Max service pressure Direction of flow Mark e g CE UKCA if required Year of construction Serial number Type of vessel Weight Body of regulations Test pressure Test date Volume Task and function Purpose The TD steam drier steam purifier is installed in steam systems The equipment is used to separate water susp...

Страница 8: ...tatic charging is the responsibility of the manufacturer or operator of the system Indoor air clean salt free and non corrosive Temperature 5 40 C Make sure that all these requirements are always met when storing the equipment Storing and transporting the equipment Please contact the manufacturer if you cannot comply with the recommended storage conditions Transporting the equipment Attention Equi...

Страница 9: ...hot or hazardous fluid is in the equipment or the pipes Make sure that the pipes upstream and downstream of the equipment are depressurised Make sure that the installation is switched off and protected against unauthorised or unintended activation Make sure that the equipment and the pipes have cooled down to room temperatures Wear protective clothing that is suitable for the fluid and if necessar...

Страница 10: ...ue to damaged seals can harm the environment Make sure that sealing surfaces are undamaged Clean sealing surfaces before installing a new seal Replace every seal after disassembly Tighten threaded joints to the specified torque Make sure that the equipment is not under any stress when installed Equipment nominal size 200 and upwards is fitted with lugs 7 for support However these lugs are not pre ...

Страница 11: ...sure that the equipment is safely mounted and that all connections are made correctly Operation When warm check the flanged unions for tightness Do not work on the equipment while it is operating Re tighten the bolted connections if necessary During operation the surface of the equipment gets hot This presents the risk of burns Lag the surface of the equipment with suitable insulating material ...

Страница 12: ...harmful substances DANGER If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment Only qualified personnel are allowed to perform work on contaminated equipment Always wear the protective clothing prescribed for contaminated areas when working on the equipment Make sure that the equipment is completely decontami...

Страница 13: ...ten the lugs from the supports Place the equipment on a suitable surface Remove all residues from the equipment Store the equipment as described on page 8 For the disposal of all residues observe the pertinent legal regulations concerning waste disposal Re using equipment after storage Observe the following instructions if you want to remove the equipment and use it again somewhere else Removing t...

Страница 14: ...eft to right PN Material Flange Pipe Base 16 1 0460 P250GH 1 0345 P235GH N 1 0425 P265GH 16 1 4571 X6CrNiMoTi17 12 2 40 1 0460 P250GH 1 0345 P235GH N 1 0425 P265GH You can return the equipment to your contractual partner Make sure that all harmful substances are removed from the equipment Pay attention to the instructions in section Transporting the equipment from page 8 Pack the equipment in its ...

Страница 15: ...500 230 740 49 0 175 125 150 25 320 560 240 870 76 0 200 150 200 25 150 350 650 285 1 055 119 0 250 150 200 250 25 150 400 720 330 1 170 178 0 Manufacturer s declaration You can find details on the conformity of the equipment in our Declaration of Conformity or Manufacturer s Declaration GESTRA AG Münchener Straße 77 28215 Bremen Germany You can download the latest Declaration of Conformity or Man...

Страница 16: ...world www gestra de GESTRA AG Münchener Strasse 77 28215 Bremen Germany Phone 49 421 3503 0 Fax 49 421 3503 393 e mail info de gestra com Web www gestra com 819479 02 05 2021 kx_mm 808935 03 GESTRA AG Bremen Printed in Germany ...

Отзывы: