6 Maintenance

6.1 Maintenance 

plan

weekly

every six 

months or 

500 operating 

hours

as required

6.2.1  Clean water fi lter

6.2.2  Clean high pressure nozzle

6.2.3  Check oil level

6.2.4  Change oil - 

Note:

 First time after 50 hours

Maintenance of motor according to separate operating instructions from the engine supplier

6.2 Maintenance 

work

6.2.1 Clean water fi lter

A water fi lter is fi tted on the 
water inlet to prevent large 
particles of dirt from entering 
into the pump.

1. Unscrew the union nut.
2. Remove the fi lter and rinse it. 

Replace damaged fi lter.

3. Tighten the union nut gently, 

so as to avoid damaging the 
gasket.

6.2.2 Clean high pressure 

nozzle

A blocked nozzle causes 
excessive pump pressure. It 
must therefore be cleaned 
immediately.

1. Stop the washer.
2. Remove the lance.
3. Clean the nozzle with a  

needle.

4. Rinse the lance with water 

from the nozzle side.

WARNING!

Use the cleaning needle only 
when the spray lance has been 
removed.

NOTE!

The fuel engine 

stops automatically 

if the oil level is low. You can 
start the petrol engine again 
once you have added oil (does 
not apply to POSEIDON 2-31 
PE).

Содержание POSEIDON 2-31

Страница 1: ...POSEIDON 2 31 3 36 5 67 PE POSEIDON 5 54 DE User Manual...

Страница 2: ...Copyright 2007 Gerni...

Страница 3: ...se 6 2 2 Operating elements 6 3 1 Setting up the pressure washer 7 4 1 Connections 7 4 2 Start the pressure washer 8 4 3 Using detergents 9 5 1 Switching off the pressure washer 10 5 2 Disconnecting s...

Страница 4: ...hat the high pressure cleaner is in a safe and proper condition Operate the pressure washer only in an upright position Important notes Do not connect the pressure washer directly to the public drinki...

Страница 5: ...ages of water result in severe damage to the pump seals Maintenace and repair CAUTION Before cleaning and servicing the high pressure washer always remove the ignition plug cable first Carry out only...

Страница 6: ...stry construction industry etc 2 2 Operating elements 1 Start stop switch 2 Lance 3 Holder for lance 4 Holder for high pressure hose 5 High pressure hose 6 Spray gun 7 Water connection and water inlet...

Страница 7: ...forward and lock it by turning it to the left 2 Insert the nipple of the lance into the quick coupling and turn the blue quick coupling grip to the right 3 Pull the lance or other accessory forward to...

Страница 8: ...supply 1 Start the engine See the operating manual for the fuel engine 2 Unlock the spray gun and operate it 3 Lock the safety catch even during short pauses NOTE Operate the spray gun several times a...

Страница 9: ...ill turn off If not stop the machine immediately and contact Gerni service department 4 The machine can be started by means of the starter rope if the battery has gone flat See manual from Yanmar 4 3...

Страница 10: ...without danger of frost IMPORTANT If the high pressure washer is stored in a room with temperatures around or below 0 C anti freeze should be drawn into the pump beforehand 1 Remove the water inlet h...

Страница 11: ...ntering into the pump 1 Unscrew the union nut 2 Remove the filter and rinse it Replace damaged filter 3 Tighten the union nut gently so as to avoid damaging the gasket 6 2 2 Clean high pressure nozzle...

Страница 12: ...ump gear oil 1 Before changing the oil allow the pressure washer to become warm 2 Unscrew the plugs at the top and the bottom of the pump 3 Allow the oil to drain into a suitable container min 1 l cap...

Страница 13: ...e control is defective accessory Low fuel level Low oil level in engine The pump is blocked or frozen Remedy Vent the system by operating the spray gun several times at short intervals If necessary di...

Страница 14: ...nty Your Gerni product is guaranteed for 12 months from date of purchase purchase receipt must be presented on the following conditions that defects are attributable to flaws or defects in materials o...

Страница 15: ...specifications POSEIDON 2 31 PE POSEIDON 3 36 PE POSEIDON 5 67 PE POSEIDON 5 54 DE Working pressure bar 140 140 230 195 Water volume Qmax l h 700 840 1150 1000 Water volume QIEC l h 650 750 1100 950...

Страница 16: ...106169230 01 2007 Nilfisk Advance Pty LTd 48 Egerton St Silverwater NSW 2128 Phone 1300 556 710...

Отзывы: